Safety temperature limiter for heat pump in conjunction with an external one heat
generator.
A
- Clamps on the extended installation board
B
- Place the bridge from X3.1 on 222.3
C
- Connection to an external heat source to the
terminals "External demand"
D
- Zabezpieczający ogranicznik temperatury do
SKKrony pompy ciepła (maks. 70°C)
K1 relay
■ Dimensioning according to the external heat
generator
■ Comply with the safety regulations
Plug 224
Clamps
Function
Description
224.4
Flow heater control DHW, grade 2
Connection parameters
■
Power: 10 W
■
Voltage: 230V~
■
Max. contact current: 4 (2) A
224.7
Circulation pump to the DHW
heating
or
immersion heater control
Connection parameters
■
Power: 100 W
■
Voltage: 230V~
■
Max. contact current: 4 (2) A
Control and load circuit of instantaneous water heater
A
- Control and load circuit of
instantaneous water heater
B
- Connection on the motherboard
and extended installation plate
211.3 1. st grade
224.4 2. st grade