Mounting on a substrate with bracket, entries above ground level
b
- Distance from the wall when passed to the wire above ground level: see "Minimum
clearances"
A
- Brackets for ground installation
B
- Bottom sheet openings for free condensate drain: Do not close holes
C
- Foundation belts
E
- Protection against freezing of the foundation (compacted gravel, e.g. from 0 to
32/56 mm), layer thickness in accordance with local requirements and construction
technology rules
F
- Electrical wires connecting the internal module to the external module and
supplying the electrical wire of the external module: Lay the wires without stress
G
- Pipe clamping ring with EPDM insert
H
- Tubular fitting for vibration compensation in hot gas line.
We recommend installing a tubular fitting to compensate for vibrations especially
in lines < 5 m.
K
- Pavement, terrace
L
- Soil
M
- Flexible separation layer between the foundation and the building