84
DHW cylinder with one temperature sensor at the top applies to the following versions:
■
DHW cylinder with temperature sensor at the top
"Top"
■
The top section of the DHW cylinder is heated to the "Set DHW temperature", e.g.
when there is little DHW demand.
"Standard"
■
The top section of the DHW cylinder is heated to the "Set DHW temperature".
"Temp. 2"
■
The top section of the DHW cylinder is heated to the "Set DHW temperature 2": Se
DHW cylinder with two temperature sensors, applies to the following version:
■
DHW cylinder with temperature sensors at the top and bottom
"Top"
■
The top section of the DHW cylinder is heated to the "Set DHW temperature", e.g.
when there is little DHW demand.
"Standard"
■
The entire volume of the DHW cylinder is heated to the "Set DHW temperature".
"Temp. 2"
■
The entire volume of the DHW cylinder is heated to the "Set DHW temperature 2".
Setting start optimisation
Start optimisation ensures that DHW is available at the set temperature at the beginning
of a time phase in the time program- DHW heating starts automatically earlier.
1. Extended menu:
2. "DHW"
3. "Start optimisation"
Setting stop optimisation
The stop optimisation ensures that the DHW cylinder is always fully heated at the end
of the time phase in accordance with the time program.
1. Extended menu:
2. "DHW"
3. "Stop optimisation"