10.26
Section 10
Reassembly
Install Oil Sentry
™
(If Equipped)
1. Apply pipe sealant with Teflon
®
(Loctite
®
No.
59241 or equivalent) to the threads of the Oil
Sentry
™
switch and install it into the 1/8” port in
the closure plate. See Figure 10-106. Torque the
switch to
10.1 N·m (90 in. lb.)
.
3. Install the two cylinder shrouds and secure with
the shoulder screws. Torque the screws to
4.0 N·m (35 in. lb.)
for initial installations, or
2.0 N·m (17.7 in. lb.)
for reinstallations. See
Figure 10-108.
Figure 10-106. Oil Sentry
TM
Pressure Switch
Location.
2. Connect the green wire lead to the Oil Sentry
™
terminal.
Install Blower Housing and Cylinder
Shrouds
1. Align and install the blower housing. See Figure
10-107.
Figure 10-107. Installing Blower Housing.
2. Secure the blower housing with the four
shoulder screws. Torque the screws to
4.0 N·m (35 in. lb.)
for initial installations, or
2.0 N·m (17.7 in. lb.)
for reinstallations.
Figure 10-108. Installing Cylinder Shrouds.
Install Control Panel (If Equipped)
1. Install the control panel to the main control
bracket and oil filter housing. Torque the M6
screw going into the oil filter housing to
10.7 N·m
(95 in. lb.)
into a new hole, or
7.3 N·m (65 in. lb.)
into a used hole. Torque the two upper M5
screws to
6.2 N·m (55 in. lb.)
into new holes, or
4.0 N·m (35 in. lb.)
into used holes. See Figure
10-109.
2. Connect the Oil Sentry
TM
indicator light wires.
3. Install the knobs onto the control levers.
Figure 10-109. Control Panel.
Mounting
Locations
Cylinder
Shrouds
Control Panel
Key Switch
Indicator
Light
Control Lever
Knobs
Mounting
Locations