Original Operating Manual for KLARO Small Wastewater Treatment Plant V.15.07
Control KLbasic/KL24base
Control KLplus/KL24plus
5.1.
Connections to the KL-controls (230V option for solenoid valves)
The connectors and fuses are located on the back of the controller, KLbasic and KLplus.
Attention: Before performing any work on the electrical system, the maintenance switch must
be switched to the "0" position (OFF) and the mains plug disconnected!
Figure 7: View of the Back of the Controller KLbasic
Connections:
1 connection for power supply
230 VAC 50 Hz,
2 X1: Bayonet connection for solenoid valves,
3 X2: Shockproof coupling for connection of air
compressor,
4 COM: Connection for communication module
(optional) or interface for PC,
5 F1: T8A fuse, medium time-lag, for mains
connection,
6 F2: T2A fuse, delay-action, for connected
consumers,
7 X4: Connection for extension cable: external
alarm.
Figure 8: View of the Back of the Controller KLplus
Connections:
1
connection for power supply
230 VAC 50
Hz,
2
X1: Bayonet connection for solenoid
valves,
3
X2: Shockproof coupling for connection of
air compressor,
4
COM: Connection for communication
module, (optional) or interface for PC,
5
F1: T8A fuse, for mains connection,
6
F2: T2A fuse, delay-action, for connected
consumers,
7
connection for temperature sensor, "must
be plugged in!"
8
X3: Connection for extension cable: UV
module and metering pump,
9
X4: Connection for external alarms and
contactor monitoring.
10 P: Connection for pressure measuring
tube.
5.2.
Connections to the KL24 controller(24V option for stepper motor valves)
The connectors/cables and fuses are located on the back of the controller KL24base and KL24plus
KLplus.
Attention: Before performing any work on the electrical system, the maintenance switch must
be switched to the "0" position (OFF) and the mains plug disconnected!
KLARO GmbH
Original Operating Manual for KLARO Small Wastewater Treatment Plant V.15.07
17
Control KLbasic/KL24base
Control KLplus/KL24plus
Figure 9: View of the Back of the Controller KL24base
Connections:
1 connection for power supply
230 VAC 50 Hz,
2 X1: Valve cable, prefabricated,
3 X2: Shockproof coupling for connection of air
compressor,
4 COM: Connection for communication module,
(optional) or interface for PC,
5 F1: T6.3A main fuse, delay-action.
1 X1.1 valve 1 24 VDC
2 X1.2 valve 2 24 VDC
3 X1.3 valve 24 VDC
4 X1.4 valve 24 4 VDC
5 X1.5 Alarm 24VDC
Figure 10: View of the Back of the Controller
KL24plus
Connections:
1
connection for power supply
230 VAC 50
Hz,
2
X1: Valve cable, prefabricated,
3
X2: Shockproof coupling for connection of
air compressor,
4
COM: Connection for communication
module, (optional) or interface for PC,
5
F1: T6.3A main fuse, delay-action,
6
F2: T2A fuse for UV module, delay-action,
7
connection for temperature sensor, "must
be plugged in!"
9
X3: Connection for UV module
10 P: Connection for pressure measuring
tube.
1 X1.0 fan 24VDC
2 X1.1 valve 1 24 VDC
3 X1.2 valve 2 24 VDC
4 X1.3 valve 24 3 VDC
5 X1.4 valve 24 4 VDC
6 X1.5 Alarm 24VDC
7 X1.6 metering pump 24 VDC
5
4
3
1
2
7
6
5
4
3
1
2
KLARO GmbH
2
Original Operating Manual for KLARO Small Wastewater Treatment Plant V.15.07
IMPORTANT:
•
This Operating Manual contains information about the plant, from installation
to maintenance, and must therefore be read before commissioning of the
plant!
•
All safety instructions must be observed!
•
The Operating Manual must be kept readily available during the operation of
the plant!
Plant Specifications
For any questions in the course of the operation of the plant, the specifications of your plant should
be noted as follows. With the help of this information, our staff will be able to help you more quickly
in the event of a malfunction. The specifications can be found on the nameplate, which is located
on the outside of the cabinet door for indoor cabinets, and inside the cabinet for outdoor cabinets.
Small Wastewater Treatment
Plant
PT
Sludge storage
Buffer
SB-Reactor
Approval No.:
Process class:
Certified:
Cabinet:
Controller:
Compressor:
Denomination:
Serial No.:
Article No.:
Additional module:
Article No.:
El. Connected load:
KLARO GmbH
2
Original Operating Manual for KLARO Small Wastewater Treatment Plant V.15.07
IMPORTANT:
•
This Operating Manual contains information about the plant, from installation
to maintenance, and must therefore be read before commissioning of the
plant!
•
All safety instructions must be observed!
•
The Operating Manual must be kept readily available during the operation of
the plant!
Plant Specifications
For any questions in the course of the operation of the plant, the specifications of your plant should
be noted as follows. With the help of this information, our staff will be able to help you more quickly
in the event of a malfunction. The specifications can be found on the nameplate, which is located
on the outside of the cabinet door for indoor cabinets, and inside the cabinet for outdoor cabinets.
Small Wastewater Treatment
Plant
PT
Sludge storage
Buffer
SB-Reactor
Approval No.:
Process class:
Certified:
Cabinet:
Controller:
Compressor:
Denomination:
Serial No.:
Article No.:
Additional module:
Article No.:
El. Connected load:
16