PWX
93
PWX750ML
6
S
pe
cificati
ons
General
Weight (main unit only)
Approximately 5 kg (11.02 lb)
Dimensions
See the outline drawing
Environmental
conditions
Operating
environment
Indoor use, overvoltage category II
Operating
temperature
0 °C to +50 °C (32 °F to +122 °F)
Operating humidity
20 %rh to 85 %rh (no condensation)
Storage temperature
-20 °C to +70 °C (-4 °F to +158 °F)
Storage humidity
90 %rh or less (no condensation)
Altitude
Up to 2000 m
Cooling method
Forced air cooling using fan
Grounding polarity
Negative grounding or positive grounding possible
Isolation voltage
±250 V max.
Isolated Analog Interface
1
1
Factory Option.
±60 V max
Withstand
voltage
Between input and FG
No abnormalities at 1500 Vac for 1 minute
Between input and output
No abnormalities at 2000 Vac for 1 minute
Between output and FG
No abnormalities at 500 Vdc for 1 minute
Between input and Iso-
lated Analog Interface
No abnormalities at 2650 Vac for 1 minute
Between output and Iso-
lated Analog Interface
No abnormalities at 500 Vdc for 1 minute
Insulation
resistance
Between input and FG
500 Vdc, 100 M
Ω
or more (70 % or less)
Between input and output
500 Vdc, 100 M
Ω
or more (70 % or less)
Between output and FG
500 Vdc, 40 M
Ω
or more (70 % or less)
Safety
2
2
Does not apply to specially ordered or modified PWX750MLs.
Complies with the requirements of the following standard.
IEC61010-1:2001
Class I
3
, Pollution degree 2
3
This is a Class I equipment. Be sure to ground this product’s protective conductor terminal. The safe-
ty of this product is only guaranteed when the product is properly grounded.
Accessories
Power cord
1 pc.
OUTPUT terminal cover
1 pc.
Output terminal bolt set
M6 bolts: 2 sets
(Bolt, nut, spring washer, and washer for each bolt)
Chassis connection wire
1 wire
J1 connector plug kit
1 set (housing × 1, connector × 1, plug × 1,
cable strain relief × 1, clip × 2, and two kinds of screws × 2)
Packing list
1 copy
Quick reference
Japanese: 1 copy, English: 1 copy
Safety precautions
1 copy
CD-ROM
1 disc
Summary of Contents for PWX750ML
Page 6: ...6 PWX Appendix A Options 100 B Troubleshooting 102...
Page 52: ...52 PWX This page is intentionally blank...
Page 80: ...80 PWX This page is intentionally blank...
Page 81: ...Maintenance This chapter explains how to perform cali bration DELETE...
Page 84: ...84 PWX This page is intentionally blank...
Page 99: ...Appendix A Options B Troubleshooting...
Page 106: ...106 PWX This page is intentionally blank...
Page 109: ......