90
PWX
PWX750ML
Control features
Other features
External
control
1
1
J1 connector on the rear panel
Output voltage control
(VPGM)
0 % to 100 % of the rated output voltage
Selectable control voltage range: 0 V to 5 V or 0 V to 10 V
Accuracy
5 % of rtg
Output current control
(IPGM)
0 % to 100 % of the rated output current
Selectable control voltage range: 0 V to 5 V or 0 V to 10 V
Accuracy
5 % of rtg
Output on/off control
OUTPUT ON/OFF CONT
Possible logic selections:
Turn the output on using a LOW (0 V to 0.5 V) or short-circuit,
turn the output off using a HIGH (4.5 V to 5 V) or open-circuit.
Turn the output on using a HIGH (4.5 V to 5 V) or open-circuit,
turn the output off using a LOW (0 V to 0.5 V) or short-circuit.
Output shutdown control
SHUT DOWN
Turns the output off with a LOW (0 V to 0.5 V) or short-circuit.
Alarm clear control
ALM CLR
Clears alarms with a LOW (0 V to 0.5 V) or short-circuit.
Master-slave parallel operation
Including the master unit, up to four units (all the same
model) can be connected.
Series operation
Up to two units (all the same model) can be connected.
Preset memory
Up to three sets of the following settings can be saved: the
set voltage, the set current, the set OVP, the set OCP, and
the set UVL.
Key lock
Locks the operation of all keys other than the OUTPUT key.
Multichannel
(VMCB)
Between master unit and
PC
LAN, USB, RS232C
Slave unit
LAN
Summary of Contents for PWX750ML
Page 6: ...6 PWX Appendix A Options 100 B Troubleshooting 102...
Page 52: ...52 PWX This page is intentionally blank...
Page 80: ...80 PWX This page is intentionally blank...
Page 81: ...Maintenance This chapter explains how to perform cali bration DELETE...
Page 84: ...84 PWX This page is intentionally blank...
Page 99: ...Appendix A Options B Troubleshooting...
Page 106: ...106 PWX This page is intentionally blank...
Page 109: ......