88
PWX
PWX750ML
Display function
Voltage
display
Maximum display
99.99 (fixed decimal point)
Display accuracy
±(0.2 % of rdng + 5 digits)
Current
display
Maximum display
99.99 (fixed decimal point)
Display accuracy
±(0.5 % of rdng + 5 digits)
Power display
1
1
Press PWR DSPL to display the power on the ammeter. Each time you press this key, the display
switches between power and current.
The PWR DSPL key lights in red.
Maximum display
9999
Display accuracy
Displays the result of multiplying the current and voltage
Operation
display
OUTPUT ON/OFF
Output on:OUTPUT LED lights in green.
Output off:OUTPUT LED turns off.
The output is on and a protection function has been activated:
OUTPUT LED blinks in orange.
CV operation
CV LED lights in green.
CC operation
CC LED lights in red.
Alarm operation
ALM LED lights in red when a protection function has been
activated.
ALM LED blinks in red when the power limit (POWER LIMIT)
has been activated.
Remote operation
REMOTE LED lights in green during remote control.
LAN
operation
LAN LED lights or blinks depending on the LAN communica-
tion status.
No fault status: Lights in green.
Fault status: Lights in red.
Standby status: Lights in orange.
WEB identify status: Blinks green.
Key lock operation
LOCK LED lights in green when the keys are locked.
Preset memory
When a preset memory entry is being used, the PRESET A, B,
or C LED lights in green.
Summary of Contents for PWX750ML
Page 6: ...6 PWX Appendix A Options 100 B Troubleshooting 102...
Page 52: ...52 PWX This page is intentionally blank...
Page 80: ...80 PWX This page is intentionally blank...
Page 81: ...Maintenance This chapter explains how to perform cali bration DELETE...
Page 84: ...84 PWX This page is intentionally blank...
Page 99: ...Appendix A Options B Troubleshooting...
Page 106: ...106 PWX This page is intentionally blank...
Page 109: ......