PWX
75
Master-Slave Parallel Operation
Parallel
/Series Operation
4
CONFIG parameters that can be set on master units
• CF00
Resets the panel settings
• CF02 Power-on
status
parameter
• CF04
Memory content display parameter
• CF05
CC control using an Vext or Rext
• CF06
CV control using an Vext or Rext
• CF07
CV/CC control range parameter
• CF09
External control parameter for turning output on and off
• CF10
External control logic parameter for turning output on and off
• CF12
Output-on startup state parameter
• CF14
Current setting limit
• CF15
Voltage setting limit
Starting master-slave parallel operation
Turning power on
1
Turn the master unit’s POWER switch on.
2
Turn the POWER switch of each slave unit on.
3
Operate the master unit normally.
You cannot perform panel operations on the slave units. Turn output on and off from
the master unit.
Turning power off
1
Turn the slave unit’s POWER switch off.
2
Turn the master unit’s POWER switch off.
CAUTION
After you turn the POWER switch off, wait at least 10 seconds after the panel display turns
off before you turn the POWER switch back on. Repeatedly turning the POWER switch on
and off at short intervals can cause damage to the inrush current limiter. In turn, this will
shorten the service life of the POWER switch, internal input fuse, and other components.
Summary of Contents for PWX750ML
Page 6: ...6 PWX Appendix A Options 100 B Troubleshooting 102...
Page 52: ...52 PWX This page is intentionally blank...
Page 80: ...80 PWX This page is intentionally blank...
Page 81: ...Maintenance This chapter explains how to perform cali bration DELETE...
Page 84: ...84 PWX This page is intentionally blank...
Page 99: ...Appendix A Options B Troubleshooting...
Page 106: ...106 PWX This page is intentionally blank...
Page 109: ......