30
MMI model
: Select the unit by model number from the dropdown.
KEP Part#
Display Type
OEM Part#
MMI1500T (640 x 480)
10.4” TFT 256 Color
MT510T…
MMI1500S (640 x 480)
10.4” STN 256 Color
MT510S…
MMI1500M (640 x 480)
10.4” STN 4 Shade Grayscale
MT510L…
MMI1050 (640 x 480)
9.4” STN 4 Shade Grayscale
MT509L…
MMI850T (640 x 480)
7.7” TFT 256 Color
MT508T…
MMI850 (640 x 480)
7.7” STN 256 Color
MT508S…
MMI750T (320 x 240)
5.7” TFT 256 Color
MT506T…
MMI750 (320 x 240)
5.7” STN 256 Color
MT506S…
MMI730T (320 x 234)
5.7” TFT 256 Color
MT506T46
MMI720 (320 x 240)
5.7” STN 4 Shade Grayscale
MT506L…
Notes:
Changing model type effects how windows are displayed.
EasyBuilder does not scale windows when display size is changed.
Example: Changing from a 640x480 to a 320x240 display clips the windows so that only the upper left corner is
shown. Changing from a 320x240 to a 640x480 display shows the window’s objects in the upper left corner.
EasyBuilder does not compensate colors so that the display is readable when changing from Color Models to Grayscale
Models.
Use the
MMI850
selection to program the discontinued
MMI1500S
.
Use the
MMI1500M
selection to program the discontinued
MMI1050
.
Use the
MMI750T
selection to program the
MMI750T
and
MMI750T-HB
.
KEP recommends that you develop a project for its target hardware platform.
(There is no utility to automatically resize a project for a larger or smaller screen.)
Serial Port I/F
: Select the PLC port’s type of hardware communications. The HMI activates the
corresponding port and configuration on the back of the unit.
Serial Port I/F
Description
RS-232
Communications to the controller are through the
PLC[RS-232]
port. (Pins
2,3 & 5)
RS-485 default
Communications to the controller are through the
PLC[RS-485] PC[RS-232]
port. This can be 2 wire or 4 wire depending on the PLC type. When unsure
select
RS-485 4W
or
RS-485 2W
.
RS-485 4W
Communications to the controller are through the
PLC[RS-485] PC[RS-232]
port. (Pins 1~5)
RS-485 2W
Communications to the controller are through the
PLC[RS-485] PC[RS-232]
port. (Pins 1,2 & 5)
Ethernet (Option)
Communications to the controller are through the optional
Ethernet
port.
Note:
RS-485 communications can be forced to 4 wire or 2 wire types. This is practical when communications adapters are
used to connect several devices to one PLC. If left at the default, it uses the PLCs default configuration.
Note:
For additional information about communication configurations for a selected PLC, see the
Controller Reference
Guide
section that refers to that PLC.
Note:
The
PLC[RS-485] PC[RS-232]
port is a dual port and serves as the programming port for the MMI. This port is also
used for Master/Slave communications (see below).