6 EDIT MENU
55
Field Programming Reference (FPRG)
6.12 CW Message Window
It can configure the CW Message to send on this window.
You can send the configured CW Message by interlocking
with the operation of function keys and the input/output
operation of the Auxiliary port.
It can control the transmission of CW Message with the
following functions.
#
Key Function
TKR-750/850/751/851 sends the configured CW
Message when the PF key is pressed if the CW
Message transmission function is assigned to the PF
key.
(Refer to 6.5 Key Assignment Window.)
#
Auxiliary Input port
TKR-750/850/751/851 sends CW Message when the
signal is applied to the Auxiliary Input port if the CW
Message transmission function is assigned to the
Auxiliary Input port.
Functions to the Auxiliary Input Ports.)
#
Save On/Off Function
TKR-750/850/751/851 sends CW Message when it
enters/exists Power Saver mode if the CW Message
transmission function is assigned to the Save On/Off
function.
(Refer to 6.4.3 Others Tab (Optional
#
Start Up Function
TKR-750/850/751/851 sends CW Message when it is
turned ON if the CW Message transmission function is
assigned to Start Up.
#
Backup Power Function
TKR-750/850/751/851 sends CW Message when the
power is switched from the main power to the backup
power if the CW Message transmission function is
assigned to the Backup Power function.
6.4.3 Others Tab (Optional Features).)
#
Main Power Function
TKR-750/850/751/851 sends CW Message when the
power is switched from the backup power to the main
power if the CW Message transmission function is
assigned to the Main Power function.
Others Tab (Optional Features).)
Figure 6-21 “CW Message” window
6.12.1 CW Message
It can configure CW Message with a maximum of 32
characters and symbols. Enter directly the message in
the edit box.
6.12.2 CW Speed
This is a speed to send CW Message. It can configure the
speed by the spin buttons or directly enter the value to
configure the speed.
6.12.3 CW Mod. Delay Time
This is a duration time to send CW message from starts
transmitting. It can configure the duration by the spin
buttons or directly enter the value to configure the
duration.
Range
No. 1 - 8
A maximum of 32 characters and symbols
(space), “, ', (,), +,,, -,., /, 0, 1, 2, 3, 4, 5, 6, 7, 8,
9,:, =,?
A - Z
Default
Blank
Range
5 - 30 word/min.
In steps of
1 word/min.
Default
20 words/min.
Range
0, 10 - 2550 ms
In steps of
10 ms
Default
600 ms