Field Programming Reference (FPRG)
50
6 EDIT MENU
AUX I/O 1 On/Off
-
AUX I/O 6 On/Off
Switch enable/disable the function assigned to the Auxiliary I/O port when the signal is applied to one of the PF
[AUX I/O 1 On/Off] to PF [AUX I/O 6 On/Off] ports.
You can assign the function when “Selectable” is configured to the Auxiliary I/O ports 1 to 6.
Assigning Functions to the Auxiliary Output Ports.)
Channel 1
-
Channel 16
Move the channel to one of CH 1 to CH 16 channels when the signal is applied to one of the PF [Channel 1] to
PF [Channel 16] ports.
You cannot configure this function when “Channel Select” is configured to Auxiliary I/O ports 1 to 4. “E2”
appears when specifying the channel without data.
(Refer to 6.10.1 AUX Select Tab.)
Channel Down
Move to the next lower channel when the signal is applied to the PF [Channel Down] input port.
The channel without data is skipped.
Channel Up
Move to the next higher channel when the signal is applied to the PF [Channel Down] input port.
The channel without data is skipped.
CW ID On
Transmit CW ID when the signal is applied to the PF [CW ID On] input port.
This function is available on the channel having the CW ID.
CW Message 1
-
CW Message 8
Transmits one of the CW Messages 1 to 8 when the signal is applied to one of the PF [CW Message 1] to PF
[CW Message 8] input ports.
(Refer to 6.12 CW Message Window.)
DC Power Save Off
Switch the Saver Mode Off when the signal is applied to the PF [DC Power Save Off] input port.
When the signal is detected with Down Edge, it cannot switch the DC Power Save function On after this
function is enabled.
DC Power Save On
Switch the Save Mode On when the signal is applied to the PF [DC Power Save On] input port.
When the signal is detected with Down Edge, it cannot switch the DC Power Save function Off after this
function is once enabled.
DC Power Save On/Off
Switch the Save Mode On/Off when the signal is applied to the PF [DC Power Save On/Off] input port.
6.4.3 Others Tab (Optional Features).)
Display Off
All LEDs other than Power SW LED located on the front panel unlit when the signal is applied to the PF [Display
Off] input port. This function is valid for only Power Saver Mode.
When the signal is detected with Down Edge, it cannot make all LEDs unlit after this function is enabled.
Display On
All LEDs on the front panel light when the signal is applied to the PF [Display On] input port. This function is
valid for only Power Saver Mode.
When the signal is detected with Down Edge, it cannot make all LEDs unlit after this function is enabled.
Display On/Off
Switch the LEDs located on the front panel On/Off when the signal is applied to the PF [Display On/Off] input
port. This function is valid for only Power Saver Mode.
Hold Time Disable
Switch Repeat Hold Time Off when the signal is applied to the PF [Hold Time Disable] input port.
It can configure this function only when at least one channel is configured as the Repeat for Operation mode
and Repeat Hold Time is enabled.
(Refer to 6.4.1 Optional Features 1 Tab.)
When the signal is detected with Down Edge, it cannot switch Hold Time On after this function is enabled.
Hold Time Enable
Switch Repeat Hold Time On when the signal is applied to the PF [Hold Time Enable] input port.
It can configure this function only when at least one channel is configured as the Repeat for Operation mode
and Repeat Hold Time is enabled.
(Refer to 6.4.1 Optional Features 1 Tab.)
When the signal is detected with Down Edge, it cannot switch Hold Time On after this function is enabled.
Hold Time Disable/
Enable
Switch disable/enable Repeat Hold Time when the signal is applied to the PF [Hold Time Disable/Enable] input
port. It can configure this function only when at least one channel is configured as the Repeat for Operation
mode and Repeat Hold Time is enabled.
(Refer to 6.4.1 Optional Features 1 Tab.)
Local TX Disable
It can disable the transmissions using the Local Mic PTT when the signal is applied to the PF [Local TX Disable]
input port. When the signal is detected with Down Edge, it cannot enable the transmission using the Local Mic
PTT after this function is enabled.
Local TX Enable
It can enable the transmission using the Local Mic PTT when the signal is applied to the PF [Local TX Enable]
input port. When the signal is detected with Down Edge, it cannot restrict the transmissions using the Local Mic
PTT after this function is enabled.
Local TX
Disable/Enable
Switch disable/enable the transmissions using the Local Mic PTT when the signal is applied to the PF [Local TX
Disable/Enable] input port. it can use this function only when the signal is detected with Down Edge.
AUX Input Trigger (AUX Input).)
Low Power Off *1
Switch the transmission power from Low to High when the signal is applied to the PF [Low Power Off] input
port. This function activates only when at least one channel is configured as High Transmission Power.
Function Name