Field Programming Reference (FPRG)
63
7 PROGRAM MENU
Table 7-2 Functions that you can adjust in PC Tuning Mode
Function
Wide/
Narrow
Description
Signalling
Reception
Frequency
-
You can adjust the VCO frequency during reception.
TKR-750/751 (VHF): Single Reference Level Adjustment
TKR-850/851 (UHF): Single Reference Level Adjustment
Reception
Frequency
(Low)
-
You can adjust the VCO frequency during reception.
TKR-750/751 (VHF) only: Single Reference Level Adjustment
You can make the adjustment in steps of 2.5 kHz.
Reception
Frequency
(High)
-
You can adjust the VCO frequency during reception.
TKR-750/751 (VHF) only: Single Reference Level Adjustment
You can make the adjustment in steps of 2.5 kHz.
Transmission
Frequency
-
You can adjust the VCO frequency during transmission.
TKR-750/751 (VHF): Single Reference Level Adjustment
TKR-850/851 (UHF): Single Reference Level Adjustment
Transmission
Frequency
(Low)
-
You can adjust the VCO frequency during transmission.
TKR-750/751 (VHF) only: Single Reference Level Adjustment
You can make the adjustment in steps of 2.5 kHz.
Transmission
Frequency
(High)
-
You can adjust the VCO frequency during transmission.
TKR-750/751 (VHF) only: Single Reference Level Adjustment
You can make the adjustment in steps of 2.5 kHz.
Squelch Tight
Wide
You can adjust the Squelch Level 15.
Single Reference Level Adjustment
Narrow
Squelch
Open
Wide
You can adjust the Squelch Level 1.
Single Reference Level Adjustment
The TKR-750/850/751/851 stores the RSSI Level at the same time.
Narrow
RD (RX
Detector
Output)
Level
Wide
You can adjust the RD (RX Detector Signal Output) level.
Single Reference Level Adjustment
Narrow
RA (RX Audio
Output)
Level
Wide
You can adjust the RA (RX Audio Signal Output) level.
Single Reference Level Adjustment
Narrow
TX High
Power
-
You can adjust the TX High Power level.
High Power: 3 Reference Level Adjustments
TX Low
Power
-
You can adjust the TX Low Power level.
Low Power: 3 Reference Level Adjustments
Power Down
Detect (High)
-
You can configure the threshold level to detect the degradation of the output power while
transmitting in High Power mode.
Single Reference Level Adjustment
Power Down
Detect (Low)
-
You can configure the threshold value to detect the degradation of the output power while
transmitting in Low Power mode.
Single Reference Level Adjustment
Max
Deviation
Wide
You can adjust the Maximum Deviation level.
TKR-750/751 (VHF): 6 Reference Level Adjustments (3 Reference levels for VCO A and B)
TKR-850/851 (UHF): 3 Reference Level Adjustments
Narrow
DQT Balance
Wide
You can adjust the DQT Encode balance.
TKR-750/751 (VHF): 2 Reference Level Adjustments
TKR-850/851 (UHF): Single Reference Level Adjustment
Sig CH = 2
Narrow
TD (Ext.
Signalling)
Deviation
Wide
You can adjust the TD (external signalling) level.
TKR-750/751 (VHF): 2 Reference Level Adjustments
TKR850/-851 (UHF): Single Reference Level Adjustment
Narrow
TA (TX
Audio)
Deviation
Wide
You can adjust the TA (TX Audio) level.
TKR-750/751 (VHF): 2 Reference Level Adjustments
TKR-850/851 (UHF): Single Reference Level Adjustment
Narrow