Field Programming Reference (FPRG)
34
6 EDIT MENU
6.4.3
Others Tab (Optional Features)
On this tab, you can activate/deactivate Power Saver
Mode and switch the power source, and configure the
functions activating when the TKR-750/850/751/851 is
turned ON.
You can configure the Save On/Off, the Start Up
operation, the “Backup Power Function”, and the “Main
Power Function”.
Figure 6-11 Others tab
Table 6-2 Available functions
Function Name
Description
None
The TKR-750/850/751/851 does not perform any operation.
AUX Out 1 Off
-
AUX Out 5 Off
The function assigned to the specified Auxiliary Output port is disabled when the TKR-750/850/751/851 starts
operation. You can assign this function when “Selectable” is configure to the Auxiliary Output ports 1 - 5.
(Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.)
AUX I/O 1 Off
-
AUX I/O 6 Off
The function assigned to the specified Auxiliary I/O port is disabled when the TKR-750/850/751/851 starts
operation. You can assign the function when “Selectable” is configured to the Auxiliary I/O ports 1 - 6.
(Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.)
AUX Out 1 On
-
AUX Out 5 On
The function assigned to the specified Auxiliary Output port is enabled when the TKR-750/850/751/851 starts
operation. You can assign this function when “Selectable” is configure to the Auxiliary Output ports 1 - 5.
(Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.)
AUX I/O 1 On
-
AUX I/O 6 On
The function assigned to the specified Auxiliary I/O port is enabled when the TKR-750/850/751/851 starts operation.
You can assign the function when “Selectable” is configured to the Auxiliary I/O ports 1 - 6.
(Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.)
Channel 1
-
Channel 16
The TKR-750/850/751/851 moves to the channel selected from CH 1 to CH 16.
You cannot configure this function when “Channel Select” is configured to Auxiliary I/O ports 1 - 4. “E2” appears on
the display when specifying the channel without data.
(Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.)
Channel Down
The TKR-750/850/751/851 moves to the next lower channel.
The channel without data is skipped.
Channel Up
The TKR-750/850/751/851 moves to the next higher channel.
The channel without data is skipped.
CW ID On
The TKR-750/850/751/851 sends the CW ID when it starts operation.
This function is available on the channel having the CW ID.
CW Message 1
-
CW Message 8
The TKR-750/850/751/851 sends the assigned CW ID from CW Messages 1 to 8 when it starts operation.
DC Power Save
Off
The TKR-750/850/751/851 exits Power Saver Mode when it starts operation. You cannot configure this function to
the Save On/Off function.
DC Power Save
On
The TKR-750/850/751/851 enters Power Saver Mode when it starts operation. You cannot configure this function to
the Save On/Off function.
Display Off
All LEDs other than the Power SW LED that is located on the front panel unlit.
This function can be enabled only when the TKR-750/850/751/851 is in Power Saver Mode.
Display On
All LEDs on the front panel light.
This function can be enabled only when the TKR-750/850/751/851 is in Power Saver Mode.
Hold Time
Disable
The TKR-750/850/751/851 disables the Repeat Hold Time.
You can configure this function only when at least one channel is configured as the Repeat for Operation mode and
the Repeat Hold Time is enabled.
Summary of Contents for TKR-750