Section 7: TSP command reference
2606B System SourceMeter® Instrument Reference Manual
7-56
2606B-901-01 Rev. B / May 2018
Details
Setting the pulse width to zero (0) seconds asserts the trigger indefinitely. To release the trigger line,
use
digio.trigger[
N
].release()
.
Example
digio.trigger[4].pulsewidth = 20e-6
Sets the pulse width for trigger line 4 to
20
μs.
Also see
(on page 7-56)
(on page 7-56)
digio.trigger[N].release()
This function releases an indefinite length or latched trigger.
Type
TSP-Link accessible
Affected by
Where saved
Default value
Function
Yes
Usage
digio.trigger[
N
].release()
N
Digital I/O trigger line (1 to 14)
Details
Releases a trigger that was asserted with an indefinite pulsewidth time. It also releases a trigger that
was latched in response to receiving a synchronous mode trigger. Only the specified trigger line is
affected.
Example
digio.trigger[4].release()
Releases digital I/O trigger line 4.
Also see
digio.trigger[N].reset()
This function resets trigger values to their factory defaults.
Type
TSP-Link accessible
Affected by
Where saved
Default value
Function
Yes
Usage
digio.trigger[
N
].reset()
N
Digital I/O trigger line (1 to 14)