HD Intelligent Speed Dome Camera
User Manual
94
2) Select "Enable";
3) Select a preset from the dropdown
list of “Preset No.” and click “Set” to link the
preset with the guard line alarming;
4)
Select a program from the dropdown list of “Programme”;
Note: One program can configure one guard area only and one area is allowed to edit
only one guard line. After saving the guard line, user can configure other guard
lines. It supports maximum 4 guard lines.
5) Select a number from the dropdown list of
“Associated Preset Bits”;
Note: If selecting
“Built-in Preset Bits”, when the device loads a preset and the preset
is not linked with any intelligent event, it will load the intelligent event linking
with built-in preset bits.
6)
Target Filter
: to set target area. Click “
Edit
” and drag the mouse in the scene to
draw a rectangle. Click “
Stop
” after finishing and drag the slide bar of “Max and Min
Target Ratio” (1% by default). Moving objects over max or below min will not trigger
an alarm when they enter the guard area(s);
7)
Area Setting
: to set guard area.
Click “
Edit
” and click mouse to draw a closed area
made up of 3 to 6 points in the scene. Right click or click the starting or ending point
to close the area. Click “Stop” to finish editing;
8)
Drag the slide bar of “Sensitivity”; the higher the sensitivity is, the easier it will trigger
an alarm;
9) Select linkage type(s), which is/are the alarm output method(s) when an event
triggers an alarm;
10) Set arming duration: the default is 24 hours displaying in blue bar, or user can
customize durations. The maximum allowed number of durations is 10 on one day
and different durations cannot overlap with each other;
Picture 7-11 Arming durations
Set duration: configure arming durations according to actual requirements.