Entering Router Parameters on the Server
1.
In the application EntraPass Global Edition - Server, click the Server Parameters icon under the
Options
tab to
open the Server parameters window.
2.
Under the
KT-NCC
tab:
•
Check the box
Inbound Server Router
.
•
Check the box
Public IP Address
.
•
Enter the
Public IP Address #1
of inbound router #1 (no. 3 in the diagram on page 32) or the
Domain Name
(no. 4 in the diagram on page 32). This address is assigned by the public network
provider with whom you are connected.
3.
Click
OK
to save the configuration and close the dialog.
Configuring the KT-NCC in EntraPass Global Edition
1.
In the application EntraPass Global Edition - Workstation, open the Gateway window that is found under
the
Devices
tab.
2.
From the
EntraPass Application
drop-down list, select the KT-NCC that you just saved in EntraPass.
3.
From the
Gateway(s)
drop-down list, select the KT-NCC gateway that you would like to configure.