Kaleidescape Premiere Line Installation Guide
Installation Checklist
Kaleidescape Part No. 101-0105-00 Rev 5
Page 173
Create installation diagrams for the network and audio/video. Note the cable
distances for all A/V, Ethernet, and control interfaces. Make sure these distances do
not exceed specifications.
With a complex HDMI path, check that the HDCP repeater device limit for each
component in the path is greater than or equal to the total number of components in
the path. Premiere line players support up to 16 downstream devices.
For each Premiere line component, take note of the following information. The
Network/Control information may need to be entered after installation is complete.
Note:
MAC addresses are listed on the
Components
page of the browser interface. Player
MAC address are also listed on the
System Summary
page of the onscreen user
interface.
Note:
The Control Protocol Device ID, or
CPDID
, is only necessary when routing commands
through a central device (e.g., a server). It is configured on the
CONTROL
tab of the
Settings
page for the individual component on the
Components
page of the browser
interface.
Type
General
Network/Control
Ser
ver
Pl
ay
er
Vault
Serial Number
Location
IP Address
St
at
ic
DH
CP
Re
se
rv
at
io
n MAC Address
CPDID
010300001234
basement rack
192.168.15.32
00:07:E9:B5:AA:38
2
020600005678
master bedroom
192.168.15.33
00:0B:63:00:75:93
3
060000012345
theater
192.168.15.34
00:0B:63:00:92:1B
4
EX
AM
PL
ES