2. Remove the battery (batteries) and store in a frost-free room.
3. Make sure batteries are fully charged.
12.1.2 Long-term de-commissioning and storage
De-commissioning the machine for 5 months or longer.
Material Oil receptacle
Preserving oil
Preservative
Desiccant
Plastic sheeting
Moisture-resistant adhesive tape
➤ The following measures must be taken for long-term decommissioning and storage:
Long-term decommissioning and storage tasks
see
chapter
Confirmed?
➤ Check engine coolant.
➤ Drain the engine oil.
➤ Drain the oil from the oil separator tank and the oil cooler.
➤ Fill the separator tank and engine with preserving oil.
➤ Run the machine for about 10 minutes to coat all parts with a protec‐
tive oil film.
–
➤ Disconnect the battery, the minus terminal first and then the plus ter‐
minal, and store in a frost-free room.
–
➤ Check the battery liquid level.
➤ Check the battery charge monthly and recharge if necessary to pre‐
vent the battery fluid freezing.
–
➤ Clean the battery terminals and coat with acid-resistant grease.
–
➤ Close the compressed air outlet valves.
–
➤ Cover the following openings with plastic foil and moisture-proof
duct tape:
■ Engine air inlet
■ Compressor air inlet
■ Exhaust silencer
–
➤ Clean the bodywork and treat with preservative.
–
➤ Attach a notice on the instrument panel informing of the decommis‐
sioning measurements taken.
–
Tab. 84 "Long-term decommissioning and storage" checklist
12 Decommissioning, Storage and Transport
12.1 Decommissioning
194
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M58utility SIGMA CONTROL SMART
No.: 901779 08 USE