Alarm codes, range 3300 – 3399 “Controller warnings”:
Code Meaning
Remedy
See
chapter
Where can I get help?
SW
KS
3303 Warning - PLC tempera‐
ture high
Check operating condi‐
tions.
Allow the machine to cool
down.
–
–
3313 Warning - HMI tempera‐
ture high
Check operating condi‐
tions.
Allow the machine to cool
down.
–
–
SW = Specialized workshop; KS = KAESER SERVICE
PLC - Programmable logic controller; HMI = Human-machine interface
Tab. 58 General warning messages and measures
9.3 Evaluating engine faults and alarms
9.3.1 Engine stops or fails to start
Possible cause
Action
Where can I get help?
SW
KS
«EMERGENCY STOP» push
button activated.
Unlock the
«EMERGENCY STOP» push
–
–
Starter faulty.
Replace starter.
X
–
Engine electrical fault.
Have it epaired/replaced.
X
–
Fuel tank empty.
Fill the fuel tank.
–
–
Air pockets in fuel line between
fuel tank and injection pump.
Bleed the fuel line, see chap‐
–
–
Fuel filter clogged.
Clean or replace, see chap‐
–
–
Fuel line broken.
Have it replaced.
X
–
Control fuse or relay fault.
Have it checked. Replace if nec‐
essary.
X
X
Airend discharge temperature
too high.
Perform check.
–
X
SIGMA CONTROL SMART con‐
troller faulty.
Arrange for it to be repaired/
replaced.
–
X
Electrical connections and/or ca‐
bles loose or broken.
Tighten. Replace cables if nec‐
essary.
X
–
Battery faulty or charge too low. Maintain battery, see chap‐
–
–
SW = Specialist Workshop; KS = KAESER SERVICE
9
Fault Recognition and Rectification
9.3
Evaluating engine faults and alarms
No.: 901779 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M58utility SIGMA CONTROL SMART
91