Material Eye protection
Cleaning cloth
Cleaning agents
High-pressure washer
Precondition The machine is standing in a cleaning area equipped with an oil separator,
the machine is standing on level ground and has cooled down.
The machine is fully vented,
the pressure gauge reads 0 psig!
The Controller ON/OFF switch is switched off,
the negative cable of the battery has been disconnected.
Stirred up dirt particles and hazardous materials!
Injury to the eyes.
➤ Wear safety glasses.
Jet water can damage the machine!
Jet water can damage or destroy electrical components and sensitive display instruments.
➤ Do not direct jet water at electrical components.
➤ Observe the separate manufacturer instructions regarding external and internal cleaning
of the machine.
➤ Deploy the extension pole of the high-pressure washer in order to maintain the necessa‐
ry distance from the object being cleaned.
➤ Keep the extension pole of the high-pressure washer in constant motion.
➤ Clean the machine carefully!
8.5.1 Cleaning the exterior of the machine
Overview:
■ Open the closed floor pan (option)
■ Check the protective covers are over all plug sockets on the exterior of the machine (options)
■ Close the control panel cover
■ Clean the exterior
■ Clean the electrical components (options)
■ Clean sensitive display instruments
Opening the closed floor pan:
In order to prevent liquid from accumulating inside the machine, the closed floor pan must be
opened.
1. Remove all plugs.
2. Clean all plugs.
8
Operation
8.5
Cleaning the machine after operation
No.: 901779 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M58utility SIGMA CONTROL SMART
79
Option oe