Danger of suffocation from toxic exhaust fumes.
Exhaust fumes from internal combustion engines contain carbon monoxide, which is odour‐
less and deadly.
➤ Use the machine only outdoors!
➤ Do not inhale exhaust fumes.
Danger of burns from hot components and sparks.
➤ Wear long-sleeved clothing and gloves.
➤ Wear eye protection.
Spark arrestor cleaning
Fig. 70 Spark arrestor cleaning
1
Machine roof
2
Spark arrestor
3
Soot drain plug
1. Unscrew the soot drain plug.
2. Push one end of the hose over the drain port and place the other end in the receptacle.
3. Start the compressor engine.
4. In order to increase the pressure in the exhaust system, partially cover the exhaust discharge
pipe with a fire-proof object.
Soot will drain through the hose into the receptacle.
5. Shut down the engine.
6. Remove the hose and replace the plug.
It is recommended to blow out the spark arrestor with compressed air once a year.
Dispose of soot according to environment protection regulations.
10 Maintenance
10.13 Maintenance for Optional Items
No.: 901779 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M58utility SIGMA CONTROL SMART
155