3. Use the small screwdriver to unscrew the nozzle
8
from the dirt trap housing.
4. Clean the nozzle, strainer, screw plug, O-ring
5
and dirt trap housing
9
with cleaning solvent
or spirit.
5. Check the nozzle, strainer and O-ring for wear.
When clearly worn: replace components.
6. Place the strainer on the screw plug.
7. Screw in the plug making sure the O-ring seats properly.
8. Screw in the nozzle and re-attach the condensate drain hose.
Putting in operation:
1. Turn on the «battery isolating switch».
2. Replace the panels.
Starting the machine and performing a test run:
1. Switch the machine on and run it in IDLE mode for approx. 5 minutes.
2. Shut down the machine.
3. Wait until the machine has automatically vented.
Pressure gauge reads 0 psig!
4. Open the outlet valves.
5. Remove both front panels.
6. Check the cyclone separator housing and hose line for leaks.
7. Replace the panels.
10.13.3 Option la
Spark arrestor cleaning
The spark arrestor must be cleaned of any soot residue every two months to prevent the emission
of glowing particles from the exhaust silencer.
Material Suitable rubber hose
Soot receptacle
Cleaning cloths
Protective gloves
Eye protection
Precondition The machine is switched off.
The machine is standing level.
The machine is fully vented, the pressure gauge reads 0 psig.
The machine has cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
10 Maintenance
10.13 Maintenance for Optional Items
154
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M58utility SIGMA CONTROL SMART