background image

COMPRESSOR 50ltR  V-twin DiRECt DRiVE 

3hP

Model no: 

SAC5030VE.V2

thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAfEty

1.1.    

ElECtRiCAl SAfEty

 

‰

  

wARninG!

 It is the user’s responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and    

 

all electrical connections for wear and damage. Sealey recommend that an RCd (Residual Current device) is used with all electrical  

 

products. You may obtain an RCd by contacting your local Sealey dealer. 

 

If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable  

 

 

Appliance Test) tested.

 

Electrical safety information, it is important that the following information is read and understood.

1.1.1.   

ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2.   

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3. 

  

important

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the    

 

correct fuse - see fuse rating in these instructions.

 

8

   DO  nOt

 pull or carry the appliance by the power cable.

 

8

  

DO nOt

 pull the plug from the socket by the cable. 

 

8

   DO  nOt

 use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or is 

  replaced immediately by a qualified electrician.

1.1.4. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

        

 If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

        

 Ensure that repairs are carried out by a qualified electrician.

        

 Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

 a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

 b) Connect the BROWN live wire to the live terminal ‘L’.

 

 c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

       

 ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

        

 Sealey recommend that repairs are carried out by a qualified electrician. 

1.2.    GEnERAl SAfEty 

 

9

   Familiarise yourself with the application and limitations of the compressor.

 

9

   Ensure the compressor is in good order and condition before use. If in any doubt do not use the unit and contact an electrician/service  

 agent.

 

‰

   wARninG! 

Compressor must only be serviced by an authorised agent. DO NOT tamper with, or attempt to adjust, pressure  

  switch or safety valve.

 

9

   Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been  

 vented.

 

9

   Maintain the compressor in good condition and replace any damaged or worn parts. Use genuine parts only. 

Unauthorised parts may be  

  dangerous and will invalidate your warranty.

 

9

   Read the instructions relating to any accessory to be used with this compressor. ensure the safe working pressure of any air appliance  

 used 

exceeds compressors output pressure. If using a spray a gun, check that the area selected for spraying is provided with an air    

  change/ventilation system.

 

9

   ensure the air supply valve is turned off before disconnecting the air supply hose.

 

9

   To move the compressor use the handle only. Maintain unit’s centre of gravity when lifting. 

DO nOt

 attempt to lift or move  

 

  the compressor by any other means. 

 

9

   Use the compressor in a well ventilated area and ensure it is placed on a firm surface.

 

9

   Keep tools and other items away from the compressor when it is in use, and keep area clean and clear of unnecessary items.

 

9

   ensure the air hose is not tangled, twisted or pinched.

 

9

   Keep children and unauthorised persons away from the working area.

 

8

  

DO nOt

 dis-assemble compressor for any reason. The unit must be checked by qualified personnel only.

 

8

  

DO nOt

 use the compressor outdoors, or in damp, or wet, locations.

 

8

  

DO nOt

 operate within the vicinity of flammable liquids, gases or solids.

 

8

  

DO nOt

 touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot.

S

AC5030VE.V2 Issue 5 (HF) 25/05/18

Original Language Version

© Jack Sealey limited

Refer to 

instructions

electrical shock 

hazard

 Hot surfaces

 

Wear ear 

protection

ensure oil level 

is correct before 

first use 

 do noT 

operate the  

compressor 

with enclosure 

displaced

DO nOt

 open 

air cock before 

an air hose is 

attached

Warning 

Automatic Start 

Up

Recommended fuse rating

13 Amp

Summary of Contents for SAC5030VE.V2

Page 1: ... wire to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY 9 9 Familiarise yourself with the application and limitations of the compressor 9 9 Ensure the compressor is in good or...

Page 2: ...your supplier 4 2 Save the packing material for future transportation of the compressor We recommend that you store the packing in a safe location at least for the period of the guarantee Then if necessary it will be easier to send the compressor to the service centre 4 3 Confirm that the mains voltage corresponds with the voltage shown on the compressor data plate 4 4 Assemble the wheels fig A X ...

Page 3: ...ig 3 6 indicates the pressure inside the main tank The smaller gauge fig 3 5 indicates the pressure supplied to the air equipment Should the pressure in the main tank exceed the pre set switch fig 3 8 maximum the safety valve fig 3 7 will activate WARNING For this reason DO NOT tamper with or adjust the switch or safety valve 5 3 7 The compressor is fitted with a reset trip located in the connecti...

Page 4: ...nk Tank could rupture or explode Cannot be repaired DISCONTINUE USE IMMEDIATELY 4A Motor stops and will not restart Thermal cut out has operated Allow unit to cool for 30 minutes before restarting 4B Motor stops and will not restart Supply fuse has tripped Press trip reset button fig 7 and restart unit If repeated tripping occurs replace the check valve or contact authorised Service Agent 5 Compre...

Reviews: