GNATUS 150L Owner'S Manual Download Page 1

Summary of Contents for 150L

Page 1: ......

Page 2: ...ini industrial LTDA C N P J 59 064 766 0001 82 Avenida Professora Luiza Garcia Ribeiro 130 Santa Rosa de Viterbo SP Brasil For improved safety Read and understand all the instructions contained in the Instructions for use before installation or operation of this equipment Note The Instructions for use must be read by all persons that operate this equipment ...

Page 3: ...warnings during the installation of the equipment 17 Recommendations for preserving the equipment 17 Precautions and warnings during the use of equipment 18 Precautions and warnings after the use of equipment 18 Precautions and warnings during the cleaning of equipment 18 Precautions in case of alteration in the functioning of equipment 18 Precautions to be adopted against foreseeable or uncommon ...

Page 4: ...be operated and utilized by specialized professional certified professional according to the legislation of the country and following the instructions of the manual The operation of the equipment required for the professional the utilization of correct instruments and it should to be in perfect conditions of the use and to protect the professional the patients and others in the eventual danger sit...

Page 5: ...tate the equipment s operation and maintenance Safety System with valve that starts running for pressure release if there is any failure from the pressure switch and overload shield in order to protect the equipment from overheating Models with tanks of 40 65 and 150 liters both with internal antioxidant painting ensuring greater durability of the compressor Principles and fundamentals applied to ...

Page 6: ...e 05 On off switch 06 Inner pressure gauge manometer 07 Safety valve 08 Overload protector 09 Register of the outlet pressure 10 Manometer of the outlet pressure 11 Outflow rate register 12 Drainage register 07 06 10 11 09 09 04 04 04 04 04 05 08 03 03 03 03 03 01 02 12 07 07 06 06 10 10 11 11 09 05 05 08 08 01 01 02 02 12 12 ...

Page 7: ...ures Supply voltage and frequency 40 and 65 Liters 220V 10 60Hz or 220V 10 50Hz or 127V 10 60Hz Supply voltage and frequency 150 Liters 220V 10 60Hz Rated current 40L 127V 8 5 A 40L 220V 4 8 A 65L 127V 12 5 A 65L 220V 6 5 A 150L 220V 13 A General power and energy consumption 40L 127V 1080 VA 1 08 KW h 40L 220V 1056 VA 1 06 KW h 65L 127V 1588 VA 1 59 KW h 65L 220V 1430 VA 1 43 KW h 150L 220V 2860 V...

Page 8: ...2 cfm 65l 283 l min 10 cfm 150l 566 l min 20 cfm Max pressure 40l 120 psi 8 3 bar 65l 120 psi 8 3 bar 150l 120 psi 8 3 bar Number of Cylinders 40l 2 65l 2 150l 2x2 Other specifications Head weight 40L 10 Kg 65L 15 Kg 150L 2x15 Kg Weight with packaging 40L 39 Kg 65L 54 Kg 150L 107 Kg Weight With packaging width x length x height 40L 528x528x800 mm 65L 528x528x1060 mm 150L 545x1200x935 mm Dimensions...

Page 9: ...9 TECHNICAL SPECIFICATIONS Dimensions 40 LITERS ...

Page 10: ...10 TECHNICAL SPECIFICATIONS Dimensions 65 LITERS ...

Page 11: ...11 TECHNICAL SPECIFICATIONS Dimensions 150 LITERS ...

Page 12: ...way from direct sun light exposure Packing to be transported and or stored with care should not suffer drop and neither receive impact Temperature limit for the packing to be stored or transported Turned on position Important It indicates an instruction of safety for operation of the product Not following it can lead to serious danger to the patient Attention Check the working instructions Note It...

Page 13: ...xecute this task Gnatus bears no responsibility for damages or accidents caused by poor installation executed by a technician not authorized by Gnatus Only after the equipment has been installed and duly tested by the authorized technician representing Gnatus will it be ready to start work operations These information also make part of the Manual of Installation and Maintenance of the equipment th...

Page 14: ...2 psi and so successively and automatically If the pressure switch fails the safety valve 07 will start running by releasing the excessive pressure Voltage Rated current Circuit breaker 127V 10 8 5 A 10 A 220V 10 4 8 A 10 A 40L 65L Wiring Diameter tread For distance up to 5m from the circuit breaker until equipment socket wiring should be 2 5 mm section from 5 to 15m 4mm wiring from 15 to 50m 6mm ...

Page 15: ...osal Open the register slowly until all the accumulated water is drained and air starts to flow again Close the register firmly so that no leakage can occur Compressed air outlet The air pressure on the outlet can be adjusted through the register 09 check the setting on the pressure gauge 10 The air outflow rate can also be adjusted in the register 12 In tandem with the pressure and flow rate regi...

Page 16: ... hPa to 1060 hPa 525 mmHg to 795 mmHg Operation altitude 2000m Attention The Equipment maintains its condition of safety and efficacy provided that it is maintained stored as mentioned in this instruction of use Thus the equipment will not lose or alter its physical and dimensional features Sensitivity to environmental conditions in normal situations of use The equipment has been planned not to be...

Page 17: ...ow capacity while using it does not exceed their technical specifications Gnatus assumes no liability for damages accidents resulting from improper use or non compliance with the instructions described in this manual Do not touch the compressor head the upper cooling part during operation even after the compressor is turned off those parts still remain hot for some time so avoid contact Make sure ...

Page 18: ... legislation of the country Pay attention to the local legislation of the country for the conditions of installation and disposal of residue Precautions to be adopted against foreseeable or uncommon risks related to the deactivation and abandoning of equipment If the equipment has any abnormality check if the problem is related to any item listed in the topic of unforeseen events failures causes a...

Page 19: ...tive Maintenance The equipment should be calibrated routinely as per the legislation in force in the country But never with a period exceeding 3 years In order to protect your equipment seek Gnatus technical assistance for periodic revisions of preventive maintenance Filter Change Keep the air filter s B clean and in good condition of usage The air filter B prevents dust from entering into the com...

Page 20: ...rrective Maintenance Gnatus states that the supplying of the circuits diagram Part lists or any other information that permits the technical assistance by the user can be requested since previously agreed between the buyer and Gnatus Overload protector The overload protector is designed to protect the equipment from overheating If the overload protector 08 trips wait for 5 minutes until the compre...

Page 21: ...he specified Connect the compressor to the correct network Wait for the regularization of network The compressor does not re aches the maximum pressure lesser efficiency works for a short period of time Pressure valve unregulated Air tank filled with water Air intake filter with excessive dirt Request the presence of a Gnatus authorized technician Drain the water from the tank page 12 Replace the ...

Page 22: ...presentative We call your attention to our authorized resellers chain Only this chain will keep your equipment constantly new because it has trained technical assistant and specific tools for the correct maintenance of your device Whenever you need demand the presence of a Gnatus technician from the nearest resale or ask through the Attendance Service Gnatus 55 16 3512 1212 EQUIPMENT S WARRANTY Th...

Page 23: ...23 ...

Page 24: ......

Reviews: