A Juniper Networks QFX5100 Virtual Chassis Fabric (VCF) is constructed using a spine-and-leaf architecture
and topology. In the spine-and-leaf architecture, each spine device is interconnected to each leaf device.
A VCF supports up to 20 total devices, and up to 4 devices can be configured into spine devices. EX4300
switches except EX4300-48MP and EX4300-48MP-S are supported in the leaf role in a QFX5100 VCF.
To understand the different hardware configurations supported, see
“Virtual Chassis Fabric Hardware
Although best practice is to use all QFX5100 switches in the VCF, you can also use EX4300 switches
except EX4300-48MP and EX4300-48MP-S as leaf devices.
Installations with combinations of QFX5100-48T, QFX3600, QFX3500, and EX4300 switches except
EX4300-48MP and EX4300-48MP-S as leaf devices in the QFX5100 VCF are called mixed mode. All VCF
installations can support 20 total devices, of which four QFX5100 devices can be configured into spine
devices.
You can install a VCF in a single rack, multiple racks, or in wire closets. You construct a VCF by configuring
and then cabling QSFP+ interfaces into Virtual Chassis ports (VCPs).
On EX4300 switches, QSFP+ ports 0 and 1 are configured as VCP by default. Non-channelized QSFP+
interfaces on EX4300 switches except EX4300-48MP and EX4300-48MP-S can be configured into VCPs.
You can also use the SFP+ uplink module ports as VCPs by configuring these ports as VCPs. The SFP+
network ports cannot be configured into VCPs. In EX4300-48MP and EX4300-48MP-S switches, you can
use only the built-in QSFP+ ports as VCPs. You cannot configure the ports on the uplink module in
EX4300-48MP and EX4300-48MP-S switches to Virtual Chassis ports (VCPs).
BEST PRACTICE:
Use 40-Gigabit QSFP+ ports as VCPs when available.
shows two QFX5100-24Q spine devices connected to a QFX5100-48S, QFX3600,
QFX3500, EX4300, and QFX5100-96S leaf devices using all QSFP+ ports as VCPs.
391
Summary of Contents for QFX3500
Page 1: ...Virtual Chassis Fabric Hardware Documentation Published 2020 11 06...
Page 225: ...Translation The emitted sound pressure is below 70 dB A per EN ISO 7779 201...
Page 229: ...205...
Page 238: ...Unterminated Fiber Optic Cable Warning 214...
Page 246: ...Restricted Access Warning 222...
Page 249: ...225...
Page 257: ...Jewelry Removal Warning 233...
Page 260: ...Operating Temperature Warning 236...
Page 271: ...DC Power Disconnection Warning 247...
Page 275: ...DC Power Wiring Sequence Warning 251...
Page 278: ...DC Power Wiring Terminations Warning 254...
Page 410: ...Figure 130 All QFX5110 VCF g050760 Figure 131 QFX5110 VCF with QFX5100 24Q Leaf Devices 386...
Page 412: ...Figure 132 QFX5100 24Q as a Leaf Device in a QFX5110 VCF 388...
Page 565: ...Table 105 System Information continued Description Field Inventory details 541...