NOTE:
Each power supply must be connected to a dedicated power source outlet.
NOTE:
If you have a Juniper Care service contract, register any addition, change, or upgrade of
hardware components at
https://www.juniper.net/customers/support/tools/updateinstallbase/
Failure to do so can result in significant delays if you need replacement parts. This note does
not apply if you replace existing components with the same type of component.
Removing a Power Supply from a QFX5110
All QFX5110 switches, except the QFX5110-32Q-CHAS are shipped from the factory with two power
supplies. Each power supply is a hot-removable and hot-insertable field-replaceable unit (FRU) when the
second power supply is installed and running. You can install replacement power supplies in the two slots
next to the fan modules without powering off the switch or disrupting the switching function.
Before you remove a power supply from a QFX5110, ensure that you have taken the necessary precautions
to prevent electrostatic discharge (ESD) damage (see
“Prevention of Electrostatic Discharge Damage” on
).
Ensure that you have the following parts and tools available to remove a power supply from a QFX5110:
•
ESD grounding strap
•
Antistatic bag or an antistatic mat
•
Phillips (+) screwdriver, number 2 (DC power supply)
CAUTION:
Replace the power supply with a new power supply within 1 minute of
removal to prevent chassis overheating.
To remove a power supply from a QFX5110 (see
1. Place the antistatic bag or the antistatic mat on a flat, stable surface.
2. Attach the ESD grounding strap to your bare wrist, and connect the strap to the ESD point on the
chassis.
427
Summary of Contents for QFX3500
Page 1: ...Virtual Chassis Fabric Hardware Documentation Published 2020 11 06...
Page 225: ...Translation The emitted sound pressure is below 70 dB A per EN ISO 7779 201...
Page 229: ...205...
Page 238: ...Unterminated Fiber Optic Cable Warning 214...
Page 246: ...Restricted Access Warning 222...
Page 249: ...225...
Page 257: ...Jewelry Removal Warning 233...
Page 260: ...Operating Temperature Warning 236...
Page 271: ...DC Power Disconnection Warning 247...
Page 275: ...DC Power Wiring Sequence Warning 251...
Page 278: ...DC Power Wiring Terminations Warning 254...
Page 410: ...Figure 130 All QFX5110 VCF g050760 Figure 131 QFX5110 VCF with QFX5100 24Q Leaf Devices 386...
Page 412: ...Figure 132 QFX5100 24Q as a Leaf Device in a QFX5110 VCF 388...
Page 565: ...Table 105 System Information continued Description Field Inventory details 541...