Chassis Alarm Messages on a QFX3600 or QFX3600-I Device
Chassis alarms indicate a failure on the device or one of its components. Chassis alarms are preset and
cannot be modified.
The chassis alarm message count is displayed on the LCD panel on the front of the device. To view the
chassis alarm message text remotely, use the show chassis lcd CLI command.
Chassis alarms on QFX3600 and QFX3600-I devices have two severity levels:
•
Major (red)—Indicates a critical situation on the device that has resulted from one of the conditions
described in
. A red alarm condition requires immediate action.
•
Minor (yellow or amber)—Indicates a noncritical condition on the device that, if left unchecked, might
cause an interruption in service or degradation in performance. A yellow alarm condition requires
monitoring or maintenance.
describes the chassis alarm messages on QFX3600 and QFX3600-I devices.
Table 133: QFX3600 and QFX3600-I Chassis Alarm Messages
Recommended Action
CLI Message
Alarm Type
Component
Replace the fan and report the failure
to customer support.
Fan Failure
Major (red)
Fans
Check the system log for one of the
following messages and report the
error message to customer support:
•
CM ENV Monitor: Get fan speed
failed.
•
Fan-number is NOT spinning @
correct speed, where fan-number
may be 1, 2, or 3.
Fan I2C Failure
Remove and check the fan for
obstructions, and then reinsert the
fan. If the problem persists, replace
the fan.
Fan fan-number Not Spinning
The fan is missing. Install a fan.
Fan/Blower Absent
Minor (yellow)
629
Summary of Contents for QFX3500
Page 1: ...Virtual Chassis Fabric Hardware Documentation Published 2020 11 06...
Page 225: ...Translation The emitted sound pressure is below 70 dB A per EN ISO 7779 201...
Page 229: ...205...
Page 238: ...Unterminated Fiber Optic Cable Warning 214...
Page 246: ...Restricted Access Warning 222...
Page 249: ...225...
Page 257: ...Jewelry Removal Warning 233...
Page 260: ...Operating Temperature Warning 236...
Page 271: ...DC Power Disconnection Warning 247...
Page 275: ...DC Power Wiring Sequence Warning 251...
Page 278: ...DC Power Wiring Terminations Warning 254...
Page 410: ...Figure 130 All QFX5110 VCF g050760 Figure 131 QFX5110 VCF with QFX5100 24Q Leaf Devices 386...
Page 412: ...Figure 132 QFX5100 24Q as a Leaf Device in a QFX5110 VCF 388...
Page 565: ...Table 105 System Information continued Description Field Inventory details 541...