Table 12: ZY04 to 12 Medium Static Indoor Blower - With Powered Convenience Outlet
Compressor 1
Compressor 2
Electric Heat Field
Installed Kit 2EK045*
4
Min Disconnect Rating
Min Disconnect Rating
/ Pwr Exh
Si
ze
(T
on
s)
N
om
in
al
U
ni
t V
ol
ta
ge
RLA LRA MCC RLA LRA MCC
OD Fan Motors (each)
Supply Blower Motor
Pwr Exh Motor
Pwr Conv Outlet
Model kW Stages Amps
1
MCA
(Amps)
2, 3
Min Fuse
/ Breaker
Size (Amps)
Max Fuse
/ Breaker
Size (Amps)
FLA LRA
MCA
w/Pwr Exh (Amps)
Min Fuse
/ Breaker
Size w/ Pwr Exh (Amps)
Max Fuse
/ Breaker
Size w/ Pwr Exh (Amps)
FLA LRA
None
-
-
-
56
60
70
60 319
58.2
60
70
62 329
11725 12
1
33.3
59.4
60
70
60 319
62.1
70
70
62 329
12525 18.6
1
51.6
82.3
90
90
76 319
85
90
90
78 329
13225 24
1
66.6
101
110
110
93 319
103.8
110 110 95 329
208-3-60 16 110 25
16 110
25
5.8
9.9
1.1
8.6
14225 31.8
2
88.3
128.1
150
150
118 319
130.9
150 150 120 329
None
-
-
-
54.9
60
70
59 324
56.9
60
70
61 329
11725 16
1
38.5
65.3
70
70
60 324
67.8
70
70
62 329
12525 24.8
1
59.7
91.8
100
100
84 324
94.3
100 100 87 329
13225 32
1
77
113.4
125
125
104 324
115.9
125 125 107 329
230-3-60 16 110 25
16 110
25
5.2
9.4
1
8.6
14225 42.4
2
102
144.6
150
150
133 324
147.1
150 150 135 329
None
-
-
-
27.4
30
35
29 157
28.4
30
35
30 160
11746 16.5
1
19.8
33.3
35
35
31 157
34.6
35
35
32 160
12846 27.8
1
33.4
50.3
60
60
46 157
51.6
60
60
47 160
13346 33
1
39.7
58.2
60
60
54 157
59.4
60
60
55 160
460-3-60 7.8 52
12
7.8 52
12
2.9
4.7
0.5
8.6
14246 41.7
2
50.2
71.3
80
80
66 157
72.6
80
80
67 160
None
-
-
-
21
25
25
23 131
21.8
25
25
23 133
11758 17
1
16.4
28
30
30
26 131
29
30
30
27 133
12 (10)
575-3-60 5.7 38.9
9
5.7 38.9
9
2.2
4.3
0.4
8.6
13458 34
1
32.7
48.4
50
50
45 131
49.4
50
50
45 133
1
Minimum Circuit Ampacity.
2
Dual Element, Time Delay Type.
3
HACR type per NEC.
4
Non-fused Disconnect. Verify on the unit nameplate that the disconnect is properly sized for the application. Units with field
installed electric heat kits may exceed the factory installed disconnect amperage rating.
INSTALLATION MANUAL ZY SERIES 3 - 10 ton 60 Hertz R-410A
52
Johnson Controls Ducted Systems
Summary of Contents for ZY Series
Page 2: ...2 INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A Johnson Controls Ducted Systems ...
Page 140: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 140 Johnson Controls Ducted Systems ...
Page 141: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 141 Johnson Controls Ducted Systems ...
Page 142: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 142 Johnson Controls Ducted Systems ...
Page 143: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 143 Johnson Controls Ducted Systems ...