Table 15: ZY04 to 12 High Static Indoor Blower - With Powered Convenience Outlet
Compressor 1
Compressor 2
Electric Heat Field
Installed Kit 2EK045*
4
Min Disconnect Rating
Min Disconnect Rating
/ Pwr Exh
Si
ze
(T
on
s)
N
om
in
al
U
ni
t V
ol
ta
ge
RLA LRA MCC RLA LRA MCC
OD Fan Motors (each)
Supply Blower Motor
Pwr Exh Motor
Pwr Conv Outlet
Model kW Stages Amps
1
MCA
(Amps)
2, 3
Min Fuse
/ Breaker
Size (Amps)
Max Fuse
/ Breaker
Size (Amps)
FLA LRA
MCA
w/Pwr Exh (Amps)
Min Fuse
/ Breaker
Size w/ Pwr Exh (Amps)
Max Fuse
/ Breaker
Size w/ Pwr Exh (Amps)
FLA LRA
None
-
-
-
49.9
50
60
53 253
52.1
60
60
56 263
11725 12
1
33.3
59.8
60
60
55 253
62.5
70
70
58 263
12525 18.6
1
51.6
82.6
90
90
76 253
85.4
90
90
79 263
13225 24
1
66.6
101.4
110
110
93 253
104.1
110 110 96 263
208-3-60 13.7 83.1 21 13.7 83.1 21
2.3
10.2
1.1
8.6
14225 31.8
2
88.3
128.5
150
150
118 253
131.3
150 150 121 263
None
-
-
-
49.9
50
60
53 260
51.9
60
60
56 254
11725 16
1
38.5
66.3
70
70
61 260
68.8
70
70
63 254
12525 24.8
1
59.7
92.8
100
100
85 260
95.3
100 100 88 254
13225 32
1
77
114.4
125
125
105 260
116.9
125 125 108 254
230-3-60 13.7 83.1 21 13.7 83.1 21
2.3
10.2
1
8.6
14225 42.4
2
102
145.6
150
150
134 260
148.1
150 150 136 254
None
-
-
-
23.6
25
25
25 130
24.6
25
25
26 127
11746 16.5
1
19.8
33.4
35
35
31 130
34.7
35
35
32 127
12846 27.8
1
33.4
50.4
60
60
46 130
51.7
60
60
48 127
13346 33
1
39.7
58.3
60
60
54 130
59.6
60
60
55 127
460-3-60 6.2 41
10
6.2 41
10
1.3
4.8
0.5
8.6
14246 41.7
2
50.2
71.4
80
80
66 130
72.7
80
80
67 127
None
-
-
-
18.1
20
20
19 105
18.9
20
20
20 102
11758 17
1
16.4
26.9
30
30
25 105
27.9
30
30
26 102
09 (8.5)
575-3-60 4.8 33
8
4.8 33
8
1.1
3.4
0.4
8.6
13458 34
1
32.7
47.3
50
50
43 105
48.3
50
50
44 102
None
-
-
-
61
70
70
66 328
63.2
70
70
68 338
11725 12
1
33.3
65.6
70
70
66 328
68.4
70
70
68 338
12525 18.6
1
51.6
88.5
90
90
81 328
91.3
100 100 84 338
13225 24
1
66.6
107.3
110
110
99 328
110
125 125 101 338
208-3-60 16 110 25
16 110
25
5.8
14.9
1.1
8.6
14225 31.8
2
88.3
134.4
150
150
124 328
137.1
150 150 126 338
None
-
-
-
60.5
70
70
65 326
62.5
70
70
67 331
11725 16
1
38.5
72.3
80
80
66 326
74.8
80
80
69 331
12525 24.8
1
59.7
98.8
100
100
91 326
101.3
110 110 93 331
13225 32
1
77
120.4
125
125
111 326
122.9
125 125 113 331
230-3-60 16 110 25
16 110
25
5.2
15
1
8.6
14225 42.4
2
102
151.6
175
175
139 326
154.1
175 175 142 331
None
-
-
-
30.2
35
35
32 161
31.2
35
35
34 163
11746 16.5
1
19.8
36.8
40
40
34 161
38.1
40
40
35 163
12846 27.8
1
33.4
53.8
60
60
50 161
55.1
60
60
51 163
13346 33
1
39.7
61.7
70
70
57 161
62.9
70
70
58 163
460-3-60 7.8 52
12
7.8 52
12
2.9
7.5
0.5
8.6
14246 41.7
2
50.2
74.8
80
80
69 161
76.1
80
80
70 163
None
-
-
-
22.3
25
25
24 126
23.1
25
25
25 128
11758 17
1
16.4
29.7
30
30
27 126
30.7
35
35
28 128
12 (10)
575-3-60 5.7 38.9
9
5.7 38.9
9
2.2
5.6
0.4
8.6
13458 34
1
32.7
50
50
50
46 126
51
60
60
47 128
1
Minimum Circuit Ampacity.
2
Dual Element, Time Delay Type.
3
HACR type per NEC.
4
Non-fused Disconnect. Verify on the unit nameplate that the disconnect is properly sized for the application. Units with field
installed electric heat kits may exceed the factory installed disconnect amperage rating.
INSTALLATION MANUAL ZY SERIES 3 - 10 ton 60 Hertz R-410A
60
Johnson Controls Ducted Systems
Summary of Contents for ZY Series
Page 2: ...2 INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A Johnson Controls Ducted Systems ...
Page 140: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 140 Johnson Controls Ducted Systems ...
Page 141: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 141 Johnson Controls Ducted Systems ...
Page 142: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 142 Johnson Controls Ducted Systems ...
Page 143: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 143 Johnson Controls Ducted Systems ...