Table 11: ZY04 to 12 Medium Static Indoor Blower - Without Powered Convenience Outlet
Compressor 1
Compressor 2
Electric Heat Field
Installed Kit 2EK045*
4
Min Disconnect Rating
Min Disconnect Rating
/ Pwr Exh
Si
ze
(T
on
s)
N
om
in
al
U
ni
t V
ol
ta
ge
RLA LRA MCC RLA LRA MCC
OD Fan Motors (each)
Supply Blower Motor
Pwr Exh Motor
Pwr Conv Outlet
Model kW Stages Amps
1
MCA
(Amps)
2, 3
Min Fuse
/ Breaker
Size (Amps)
Max Fuse
/ Breaker
Size (Amps)
FLA LRA
MCA
w/Pwr Exh (Amps)
Min Fuse
/ Breaker
Size w/ Pwr Exh (Amps)
Max Fuse
/ Breaker
Size w/ Pwr Exh (Amps)
FLA LRA
None
-
-
-
51.7
60
60
55 315
53.9
60
60
57 325
11725 12
1
33.3
54
60
60
55 315
56.8
60
60
57 325
12525 18.6
1
51.6
76.9
80
80
71 315
79.6
80
80
73 325
13225 24
1
66.6
95.6
100
100
88 315
98.4
100 100 91 325
208-3-60 16 110 25
16 110
25
5.8
9.9
1.1
14225 31.8
2
88.3
122.8
125
125
113 315
125.5
150 150 115 325
None
-
-
-
50.6
60
60
54 320
52.6
60
60
56 324
11725 16
1
38.5
59.9
60
60
55 320
62.4
70
70
57 324
12525 24.8
1
59.7
86.4
90
90
79 320
88.9
90
90
82 324
13225 32
1
77
108
110
110
99 320
110.5
125 125 102 324
230-3-60 16 110 25
16 110
25
5.2
9.4
1
14225 42.4
2
102
139.3
150
150
128 320
141.8
150 150 130 324
None
-
-
-
25.2
30
30
27 155
26.2
30
30
28 158
11746 16.5
1
19.8
30.6
35
35
28 155
31.9
35
35
29 158
12846 27.8
1
33.4
47.6
50
50
44 155
48.9
50
50
45 158
13346 33
1
39.7
55.5
60
60
51 155
56.8
60
60
52 158
460-3-60 7.8 52
12
7.8 52
12
2.9
4.7
0.5
14246 41.7
2
50.2
68.6
70
70
63 155
69.9
70
70
64 158
None
-
-
-
19.3
20
25
21 129
20.1
25
25
22 131
11758 17
1
16.4
25.9
30
30
24 129
26.9
30
30
25 131
12 (10)
575-3-60 5.7 38.9
9
5.7 38.9
9
2.2
4.3
0.4
13458 34
1
32.7
46.3
50
50
43 129
47.3
50
50
43 131
1
Minimum Circuit Ampacity.
2
Dual Element, Time Delay Type.
3
HACR type per NEC.
4
Non-fused Disconnect. Verify on the unit nameplate that the disconnect is properly sized for the application. Units with field
installed electric heat kits may exceed the factory installed disconnect amperage rating.
INSTALLATION MANUAL ZY SERIES 3 - 10 ton 60 Hertz R-410A
46
Johnson Controls Ducted Systems
Summary of Contents for ZY Series
Page 2: ...2 INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A Johnson Controls Ducted Systems ...
Page 140: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 140 Johnson Controls Ducted Systems ...
Page 141: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 141 Johnson Controls Ducted Systems ...
Page 142: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 142 Johnson Controls Ducted Systems ...
Page 143: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 143 Johnson Controls Ducted Systems ...