5-28
SM-18003
EXTERNAL INPUT/OUTPUT AND FUNCTION SETTING
Setting Condition
Setting Temperature for Automatic Reset
66 (19)
66
o
F (19
o
C)
68 (20)
68
o
F (20
o
C)
70 (21)
70
o
F (21
o
C)
72 (22)
72
o
F (22
o
C)
74 (23)
74
o
F (23
o
C)
76 (24)
76
o
F (24
o
C)
77 (25)
77
o
F (25
o
C) (Factory-Setting)
78 (26)
78
o
F (26
o
C)
80 (27)
80
o
F (27
o
C)
82 (28)
82
o
F (28
o
C)
84 (29)
84
o
F (29
o
C)
86 (30)
86
o
F (30
o
C)
(56) Automatic Reset Time (F4)
This function is utilized to set the automatic reset time with the set temperature.
The setting conditions and automatic reset time are as follows:
(55) Automatic Reset of Setting Temperature (F3)
This function is utilized to economize the operation. When this function is valid, in the case that the
set temperature is not changed for certain period of time by the function (56) “Automatic Reset Time
(F4)”, the set temperature automatically returns to (57/58) “Automatic Reset Temperature for Cooling/
Heating (F5/F6)” as following conditions. It is effective to optimize the setting temperature and provide
energy saving. However, the setting temperature is not automatically reset in the case that “Automatic
COOL/HEAT Operation” mode, or “Prohibiting Operation by Wired Controller” is set by the centralized
controller.
<Example> Automatic Reset Temperature for Cooling is 77
o
F (25
o
C)
(57) Automatic Reset Temperature for Cooling (F5)
This function is utilized to set the automatic reset temperature for FAN/COOL/DRY operation.
The setting conditions and the automatic reset temperature for cooling are as follows:
Setting Condition
Automatic Reset Time of Setting Temperature
00
30 minutes (Factory-Setting)
01
15 minutes
02
60 minutes
03
90 minutes
Setting
Temperature Change
Return to (57) Automatic Reset
Temperature for Cooling
Return to (58) Automatic Reset
Temperature for Heating
Operation Mode
* COOL
* DRY
* FAN
Operation Mode
* HEAT
Setting
Temperature Change
(56) Automatic Reset Time
Summary of Contents for CICM008B21S
Page 2: ......
Page 10: ...viii SM 18003 ...
Page 15: ...SM 18003 1 1 INSTALLATION 1 Installation ...
Page 19: ...SM 18003 2 1 OPERATION 2 Operation ...
Page 20: ...2 2 SM 18003 OPERATION 2 1 Indoor Unit Refer to the Operation Manual for Mini Cassette ...
Page 22: ......
Page 23: ...SM 18003 3 1 TROUBLESHOOTING 3 Troubleshooting ...
Page 73: ...MAINTENANCE SM 18003 4 1 4 Maintenance ...
Page 138: ......
Page 139: ...SM 18003 6 1 FIELD WORK INSTRUCTIONS 6 Field Work Instructions ...
Page 148: ...6 10 SM 18003 FIELD WORK INSTRUCTIONS 6 8 Mollier Chart for R410A f t 3 l b ...
Page 149: ...SERVICE PARTS LIST SM 18003 7 1 7 Service Parts List ...
Page 150: ...SERVICE PARTS LIST 7 2 SM 18003 Refer to the Service Parts List for Mini Cassette ...
Page 151: ......
Page 152: ... 2018 Johnson Controls Inc SM 18003 Code No LIT 12013034 Issued April 2018 ...