5-34
SM-18003
EXTERNAL INPUT/OUTPUT AND FUNCTION SETTING
(107) Display of Thermistor Temperature (P4)
This function is utilized to display the temperature of the sensor selected at (106).
(108) Setting Temperature Display during Fan Operation (P5)
This function is utilized to undisplay the setting temperature during fan mode operation.
(109) ECO Button Operation (P6)
This function is prohibiting "ECO" button operation by setting at "01"
(110) Menu Button Operation (P7)
This function is utilized to invalidate the menu button.
(111) Not Prepared (P8)
(112) Not Prepared (P9)
(113) Not Prepared (PA)
(114) Not Prepared (Pb)
(115) Not Prepared (PC)
(116) Not Prepared (q1)
(117) Not Prepared (q2)
(118) Not Prepared (q3)
(119) Not Prepared (q4)
(120) Not Prepared (q5)
(121) Not Prepared (q6)
(122) Not Prepared (q7)
(123) Not Prepared (q8)
(124) Not Prepared (q9)
(125) Not Prepared (qA)
(126) Not Prepared (qb)
(127) Not Prepared (qC)
(128) Not Prepared (qd)
(129) Dual Setpoint (for Automatic COOL/HEAT Operation) (r1)
This function is utilized to activate/deactivate dual setpoint of cooling and heating in automatic cooling
and heating operation.
This function is invalid when the function of "Automatic COOL/HEAT Operation" is invalid
.
(130) Cooling/Heating Changeover Temperature (for Automatic COOL/HEAT Operation) (r2)
This function is utilized to change the indoor temperature condition to Thermo-ON/OFF.
This function is invalid when the function of "Dual Setpoint" is invalid.
In case dual setpoint is selected in automatic heating/cooling operation, during auto mode both cooling
setpoint and heating setpoint can be selected.
By default, temperature when the heating/cooling mode changes are as follows.
Cooling mode changes to heating mode when the indoor temperature is heating setpoint -2
o
F
(-1
o
C
).
Heating mode changes to cooling mode when the indoor temperature is cooling se2
o
F
(+1
o
C
).
Setting Condition
Actual Control Temperature
00 (Standard)
2
o
F (1.0
o
C)
01
3
o
F (1.5
o
C)
02
3
o
F (2.0
o
C)
03
4
o
F (2.5
o
C)
04
5
o
F (3.0
o
C)
05
1
o
F (0.5
o
C)
Summary of Contents for CICM008B21S
Page 2: ......
Page 10: ...viii SM 18003 ...
Page 15: ...SM 18003 1 1 INSTALLATION 1 Installation ...
Page 19: ...SM 18003 2 1 OPERATION 2 Operation ...
Page 20: ...2 2 SM 18003 OPERATION 2 1 Indoor Unit Refer to the Operation Manual for Mini Cassette ...
Page 22: ......
Page 23: ...SM 18003 3 1 TROUBLESHOOTING 3 Troubleshooting ...
Page 73: ...MAINTENANCE SM 18003 4 1 4 Maintenance ...
Page 138: ......
Page 139: ...SM 18003 6 1 FIELD WORK INSTRUCTIONS 6 Field Work Instructions ...
Page 148: ...6 10 SM 18003 FIELD WORK INSTRUCTIONS 6 8 Mollier Chart for R410A f t 3 l b ...
Page 149: ...SERVICE PARTS LIST SM 18003 7 1 7 Service Parts List ...
Page 150: ...SERVICE PARTS LIST 7 2 SM 18003 Refer to the Service Parts List for Mini Cassette ...
Page 151: ......
Page 152: ... 2018 Johnson Controls Inc SM 18003 Code No LIT 12013034 Issued April 2018 ...