Servomotor series JHN, JHQ, and JL – User Manual
General technical data
Jetter AG
40
Standard configuration
4.6.1
KTY83-110; for JL1 only PTC can be used
No brake
Plain shaft
Two straight flange sockets for power and signal
Resolver
Reduced runout tolerance = R
Degree of protection: IP65
Degree of protection IP64 with JL1 motors
Derating at altitudes higher than 1000 m above sea level
4.6.2
Derating for operation at altitudes higher than 1000 m above sea level and at standstill of the motor
and a standard ambient temperature
2000 m above sea level
6 %
3000 m above sea level
11 %
4000 m above sea level
17 %
To calculate the holding torque, the permitted torque is to be derated by the following formula:
M
red
= M
0
* sqrt (1-(H-1000)/(10000)).
4.7 Design of the JHQ series
Parameter
Description
Design
B5, V1, V3
Coating
Matt black to RAL 9005
Ball Bearing Service Life
> 20,000 operating hours
Flange
Flange dimensions according to IEC standard, flange concentricity
N
;
Balancing: Vibration class
N
; dynamic balancing with half of the feather key.
Option: Reduced runout tolerance
R
Degree of protection
IP65 (without shaft seal)
Insulation class
F acc. to VDE 0350
Coolant
Natural air cooling
Cooling plate
Length of cooling plate in mm = 2.5 x motor flange size in mm; cooling plate
thickness = 3.5 mm
Cooling plate width = cooling plate length
Ambient temperature
-15 ... +40 °C
Thermal motor protection
KTY 83-110; alternative: PTC, or PT-1000
Rotor
Rare earth permanent magnets. Excellent rotor magnetic field distribution to
eliminate torque variations at low speed.
Standard configuration
4.7.1
KTY83-110
No brake
Plain shaft
Rotatable connector S-X
Resolver
Runout tolerance = N