![Jetter JHN Series User Manual Download Page 204](http://html1.mh-extra.com/html/jetter/jhn-series/jhn-series_user-manual_3905719204.webp)
Servomotor series JHN, JHQ, and JL – User Manual
Installation and commissioning
Jetter AG
204
Caution when assuming the wrong degree of protection
8.1.4
The servo motors comply with the degree of protection IP65.
CAUTION
Observe the degree of protection at installing the motor!
If an incorrect degree of protection is assumed, personal injury and damage
to property may occur.
•
Install the motor with the degree of protection required for the
application.
•
Protect the motor from harmful environmental influences.
Suitable place of installation
8.1.5
•
The motor must be easily accessible.
•
Operating temperature: +5 … +40 °C
•
Maximum operating altitude: 1000 m above sea level
•
Relative humidity: 15 ... 85 %, non-condensing
8.2 Mechanical installation
Installation location
8.2.1
The installation location must be free from conductive and corrosive substances.
For encapsulated installation, please consult the application department of Jetter AG.
Mechanical equipment, tools
8.2.2
NOTICE
Avoid damage to the servomotor!
If not handled properly, the servo motor can be damaged.
•
Do
by all means
refrain from applying hard blows or shocks to the
motor flange and shaft.
•
For fitting backlash-free power output shafts with friction locking, only
use the specifically designed tightening thread in the motor shaft.
If possible, heat the output elements before mounting.
Fitting the power output elements may only be carried out by
means of suitable tools. Please follow the instructions given by the
power output element manufacturers.
A special hint:
Use double-conical collets.