Chapter 7
Interpreting Test Results
Modem Summary results
SmartClass ADSL/Copper Tester User’s Guide
47
CONN RATE
Current upstream and down-
stream connection rates
32–1024 kbps
1
(Up)
32–8160 kbps
32–1200 kbps
2
(Up)
32–2500 kbps
MAX RATE
Maximum upstream and down-
stream connection rates
32–1024 kbps
32–8160 kbps
32–1200 kbps
32–2500 kbps
CAPACITY
The percentage of total band-
width currently used by the
actual connect rate upstream
and downstream.
0–100%
MARGIN
SNR margin upstream and
downstream
0–63.5 dB
ATTEN
The degradation of signal
strength in dB upstream and
downstream. It is the difference
in Tx power from the transmitter
to receiver
.
0–63.5 dB
RESYNC COUNT
The cumulative number of
synchronization cycles
until
manually reset.
N/A
LOS ERRORS
Loss of Signal Errors. Number
of errors due to loss of signal.
N/A
LOF ERRORS
Loss of Frame Errors. Number
of errors due to loss of framing.
N/A
LOP ERRORS
Loss of Power Errors. Number
of errors due to loss of power.
N/A
LOSS OF MAR-
GIN
Number of bins that indicate a
loss of margin.
0–511
ATUC CODE
The identification code of the
ATUC vendor. Indicates the
manufacturer of the ATUC card
in the DSLAM.
N/A
ATUC REVISION
The software revision of the
ATUC.
N/A
TX POWER
Power level, in dB, of the ADSL
signal, downstream (from the
DSLAM) and upstream (trans-
mitted by the ADSL/Copper
Tester).
1. These are ADSL1 rates. Some manufacturers allow higher ADSL1 rates.
2. These are ADSL2 rates.
Table 6
Modem Summary results (Continued)
Result
Description
Range
Summary of Contents for SmartClass
Page 1: ...SmartClass ADSL Tester Copper Tester and ADSL Copper Tester User s Guide...
Page 2: ......
Page 3: ...SmartClass ADSL Tester Copper Tester and ADSL Copper Tester User s Guide...
Page 6: ...iv SmartClass ADSL Copper Tester User s Guide...
Page 14: ...About this Guide Conventions xii SmartClass ADSL Copper Tester User s Guide...
Page 26: ...Chapter 2 Quick Tour Using the keypad 12 SmartClass ADSL Copper Tester User s Guide...
Page 48: ...Chapter 5 Copper Testing Calibrating the unit 34 SmartClass ADSL Copper Tester User s Guide...
Page 84: ...Chapter 9 Troubleshooting Resolving problems 70 SmartClass ADSL Copper Tester User s Guide...
Page 89: ......