GAMMA VERSUS MANUAL
14
COD. 1257066 Gamma VERSUS Manual v1.13
C6
Partial inversión during
closing movement
0 – OFF
1 - ON
Enable the partial inversión during closing movement, that means
that if during the closing movement a safety element is activated, it
will opens partially the door.
D1
M2 FC.OP installed
0 – OFF
1 - ON
Indicates whether, during programming, the panel has found and
memorised an End of Run on opening in motor M2 and, therefore,
will act accordingly. In most cases, it will open until this is found,
adding pulses or time if required.
D2
M2 FC.CL installed
0 – OFF
1 - ON
Indicates whether, during programming, the panel has found and
memorised an End of Run on closure in motor M2 and, therefore,
will act accordingly. In most cases, it will close until this is found,
adding pulses or time if required.
D3
M2 Open mechanical stop 0 – OFF
1 - ON
Indicates whether, during programming, the panel has found and
memorised a mechanical stop on opening in motor M2 and,
therefore, will act accordingly. In most cases, it will open until the
mechanical stop is found, adding pulses or time if required. (Only
available in control panels for DC motors).
D4
M2 Close mechanical stop 0 – OFF
1 - ON
Indicates whether, during programming, the panel has found and
memorised a mechanical stop on closure in motor M2 and,
therefore, will act accordingly. In most cases, it will close until the
mechanical stop is found. (Only available in control panels for DC
motors).
D6
Output alarm by fire alarm
+ closing security
activated
0 – OFF
1 – ON
Enable fire alarm output by a fire alarm plus a closing security
activated. In OFF, the output is activated when there is only a fire
alarm activated.
D7
Automatic opening by fire
alarm
0 – OFF
1 - ON
Enable the automatic opening by fire alarm activation. In OFF
performs an automatic closing by the same fire alarm activation.
DC
Autodetect OptoEdge IN8 0 – OFF
1 - ON
Indicates that the IN8 input is configured as optical edge input.
DD
Autodetect OptoEdge IN9 0 – OFF
1 - ON
Indicates that the IN9 input is configured as optical edge input.
DF
Flash in Autoclose
0 – OFF
1 - ON
Enable flash function during autoclose time
4.2 Numeric parameters
The numeric parameters allow defining different values of the control panels.
Note:
When the
V-DPLAY
is used to read and/or configure parameters, it must be taken into account the
following. The
V-DPLAY
card only shows the two first digits of the most weight of the value. The real value
then will be the value showed on the display multiplied by a scale factor (DPLAY factor), indicated on the third
column of the table.
Real value = showed value * DPLAY factor
For example, if, for the 33 parameter, the display shows a 2, the real value will be 2*1000=2000.
Num. Numeric
Factor
DPLAY
Description
5
Time/pulse extra
inv.
1000
Time or pulse number added in each inversion.
2D
Extratime
Hydraulic mode
1000
Extra time added after reference in hydraulic mode.
32
Max.num
movements
100000000
Limit number of panel movements as of which a special mode is enabled
(operating or notification mode) in order to indicate that door maintenance
is required.
33
Opening stop point 1000
Stop point for the opening movement. In the case of operations by pulses,
it indicates the number of pulses required to open from the ground
Summary of Contents for GAMMA VERSUS Series
Page 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door ...
Page 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13 ...
Page 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13 ...
Page 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13 ...