7.24 Recharge maneuver function
Model
All
Associated
parameters
ID
Description
Type
PB6 Recharge
maneuver
ON/OFF
Description
The recharge maneuver function allows refreshing the CLOSED and OPENED position
and ensures that the door is correctly opened and closed.
Configuration
To enable the recharge maneuver function it is needed to set to ON the
PB6
configuration parameter by means a VERSUS-PROG programming tool.
Operating
If recharge maneuver is enabled the control panel starts a 1 hour timer every time the
door enters to CLOSED or OPENED position. After this timer finishes the control panel
executes a 3 seconds opening maneuver in case of OPENED position or a 3 seconds
closing maneuver in case of CLOSED position. This maneuver is executed in order to
correctly keep the door closed or opened. After these 3 seconds maneuver the control
panel starts again a 1 hour timer in order to refresh again the position after this timer
expires.
If a normal opening or closing maneuver is executed the 1 hour timer is interrupted and
it won’t be started again until the door enters to CLOSED or OPENED position.