7.7 Close by security contact function
Model
All
Associated
parameters
ID
Description
Type
P1A
Closing by SEC.CL
ON/OFF
P49
Time to close by SEC.CL
NUMERIC
Description
The close by security contact function allows closing automatically the door after security
contact has been activated (when car has already exited/entered).
Configuration
To enable the close by security contact function it is needed to set to ON the
P1A
configuration parameter by means of a VERSUS-PROG programming tool. It is also
possible to enable or disable this function by setting the “Close by SEC.CL ON/OFF”
function to an option switch.
The
P49
configuration parameter allows modifying the pause timer that is started after
the door reaches the opened position and the security contact is activated. This
parameter can take values from 0 seconds to several minutes. The units used for this
parameter are seconds.
Operating
If the close by security contact function is enabled, when the security contact is activated
during the opening maneuver or when the door is already open, it automatically starts
closing the door from the opened position after the pause timer expires. This allows to
automatically closing the door when a car has already exited or entered to the garage.
Notes
The close by security command is lost in several cases:
-
When “stop” command is received.
-
When the number of closing security auto tests retries expires.
-
When the number of closing security inversions are reached.
-
When an “open” command is received.
Summary of Contents for GAMMA VERSUS Series
Page 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door ...
Page 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13 ...
Page 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13 ...
Page 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13 ...