GAMMA VERSUS MANUAL
53
COD. 1257066 Gamma VERSUS Manual v1.13
7.18 Automatic 8K2/optical security edge detection function
Operating
After closing security contact inhibition function is configured and enabled, in normal
operation when door is closing when it enters to the security contact inhibition zone any
security contact activation doesn’t produces an inversion maneuver.
Notes
Any manipulation or alteration of the closing security contact installation that can modify
its position or presence implies a new control panel programming sequence.
Model
All
Associated
parameters
ID
Description
Type
P5E...P60 IN
X
INPUT
P29...P31
PDC,PDD
Autodetect OptoEdge INX
ON/OFF
Associated errors
ID
Description
Type
Wr10
Security edge closing active
Warning
Wr11
Security edge opening active
Warning
Wr37
S. Optical edge opening active
Warning
Wr38
S.Optical edge closing active
Warning
Description
The security edge autotest function allows automatically test the 8K2 wired security
edges (i.e. Radioband external receiver with 8K2 output). The autotest is performed
before every opening and closing maneuvers to ensure that they are correctly working.
P3B
SEC.CL
inhib.
point
P42
Inhib.
Zone
start
point
Security
contact
inhibit.
zone
Summary of Contents for GAMMA VERSUS Series