GAMMA VERSUS MANUAL
22
COD. 1257066 Gamma VERSUS Manual v1.13
4.5 Output parameters
The output parameters allow configuring each available input of the control panel. Each output can have
different values; they are indicated on the third column of the following table.
Num Output
Available values - description
78
OUT 1:OUT 6
0
ALWAYS OFF
The output has not got a defined function
1 COURTESY
LIGHT LEVEL
Garage light level output (duration = maneuver time + programmed time)
2 COURTESY
LIGHT PULSE
Garage light pulse output (duration = programmed time)
3 FLASH
Flash
output
4 FLASH+COUR
TESY LIGHT
Flash+courtesy light by level output.
5 ELECTROLOC
K
Electrolock output
6 ELECTROBRA
KE
Electrobrake control output
7 AUTOTEST
SIGNAL
Security contact autotest output
8 OPENING
SEQ. START
Active output right at the beginning of the opening operation
9 OPENING
SEQUENCE
Active output during all the opening operation
10 CLOSING
SEQ. START
Active output right at the beginning of the closing operation
11 CLOSING
SEQUENCE
Active output during all the closing operation
12 ERROR
SIGNAL
Active output when error detection
13 PEDESTRIAN
SEQUENCE
Active output during pedestrian mode
14
PANIC SIGNAL
Active output when panic signal detection
15
GREEN LIGHT Green traffic light control output
16
RED LIGHT
Red traffic light control output
17 INSIDE
GREEN LIGHT
Green inside traffic light control output (traffic control mode)
18 INSIDE
RED
LIGHT
Red inside traffic light control output (traffic control mode)
19 OUTSIDE
GREEN LIGHT
Green outside traffic light control output (traffic control mode)
20 OUSIDE
RED
LIGHT
Red outside traffic light control output (traffic control mode)
21 INTRUSIVE
SIGNAL
Intruder detection function output
22 S.EDGE
ACTIVE
Active output when safety edge detection
23 SEC.OP
ACTIVE
Active output when opening security contact detection
24 SEC.CL
ACTIVE
Active output when closing security contact detection
25
FC.OP ACTIVE
Active output when opening limit switch detection
26
FC.CL ACTIVE Active output when closing limit switch detection
27
ALARM
Active output when alarm signal detection
28 MAX.
NUM.SEQUEN
CES
Active output when the maximum number of maneuvers is exceeded
29
ALWAYS ON
Output always active
30 MOTOR
RUNNING
Active output at any door movement
79
7A
7B
7C
90
A1
(TL-CARD-V)
OUT
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
Summary of Contents for GAMMA VERSUS Series