Configuration
System set-up:
VERSUS control panels have 3 available inputs (IN1 to IN3) or five i
the M22 model (IN1 to IN3 and IN8 and IN9) that can automatically detect 8K2 or
optical edge signal. Before configuring the parameters the selected edge has to be
connected to the control panel. In case of an 8K2 edge it can be directly connected but
in case of optical edge power supply has to be provided. Depending on the control
panel 12Vdc or 12/24Vdc outputs are available. Usually a fixed voltage output is used
to supply the optical edge. It is also possible to set a configurable output as fixed output
by setting its value to “Always ON”.
VERSUS control panels are ready to directly control WITT (
http://www.witt-
sensoric.com/
) and FRABA (
http://www.fraba.com/
) wired optical edges. Please follow
manufacturer datasheet in order to connect the optical edge to the VERSUS control
panel.
Parameters:
To configure the 3 available inputs as automatic 8K2/optical inputs
“AUTOEDGE.CL” or “AUTOEDGE.OP” input values have to be set depending if the
edge has to actuate during the opening or the closing maneuver. This configuration is
done by using
P5E
to
P60
configuration parameters by means of a VERSUS-PROG
programming tool.
After the edge is connected and the input is configured the 8K2 or optical mode
detection is performed during the normal control panel programming sequence. After
programming, this sequence detection result can be checked by using the
P29
to
P31
status parameters. If the associated input parameter is set to ON it means that an
optical edge has been detected otherwise a 8K2 edge is taken into account.
Operating
After 8K2/optical security edge automatic input function is configured in normal
operation it takes into account its activation. When the edge is activated, the control
panes executes the security inversion maneuver. If the active edge is the closing edge
Wr10
or
Wr38
warnings are displayed (8K2 or optical edge) and in this case the
inversion maneuver opens the whole door. If the active edge is the opening edge
Wr11
or
Wr37
warnings are displayed (8K2 or optical edge) and in this case the inversion
maneuver closes during 2 seconds.
Notes
Any change of the 8K2/optical edge mode (from optical to 8K2 or vice versa) implies a
new control panel programming sequence in order to detect the new edge mode.
Even the edge is active it is possible to open/close the door by means of Deadman
mode.
Summary of Contents for GAMMA VERSUS M20
Page 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door...
Page 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13...
Page 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13...
Page 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13...