GAMMA VERSUS MANUAL
43
COD. 1257066 Gamma VERSUS Manual v1.13
Operating
After connecting the “RSEC/R re RSENS transmitter“ system for the first time
the control panel detects the system and displays the
Er23
error
to inform the user that
it is necessary to program the maneuver in order to store the Radiosens configuration.
In case of using the Radiosens system the programming maneuver procedure is
different to the normal procedure. Just after finishing the maneuver programming
sequence, the control panel executes an automatic opening and closing maneuvers in
order to let the Radiosens system perform its measures and calibrations that will be
used during the normal operation. After these extra automatic maneuvers the control
panel exits the programming state.
In the opposite hand, if the maneuver has been already programmed when a
Radiosens system was connected and the RSEC/R receiver is not detected,
Er22
is
displayed to inform the user that a Radiosens system was previously programmed and
now it is not detected. In this case there are two options: RSEC/R is connected again or
control panel maneuver has to be programmed again.
In case user modifies any configuration parameter related to the Radiosens system (i.e.
P92
or
P53
) the
Er33
error will be displayed. This error means that some configuration
parameter has changed and it is needed to pass the new parameter values to the
RSENS transmitter. Because of this is necessary to synchronize the RSENS transmitter
to the RSEC/R receiver by programming again the transmitter to the receiver.
After setting-up the hardware, configured the parameters and programmed the
maneuver sequence the Radiosens system is ready. Therefore, the programmed
RSENS transmitter will be taken into account during the normal operation. These are
the operations that are performed during the normal operation:
-
Every time a closing maneuver is started the programmed RSENS transmitter is
tested (autotest process is performed). In autotest process RSEC/R tries to
communicate via radio with the RSENS transmitter. The time needed to
perform an autotest process goes from a few milliseconds to 12 seconds at
maximum (every attempt takes about 3 seconds at maximum and the maximum
number of attempts are 4). After the 12 seconds if no RSENS transmitter
answer is received an autotest error occurs. Because is a closing autotest
Er19
is displayed.
- If during normal operation Radiosens security activation is detected control
panel executes the opening security inversion maneuver and displays the
Wr18
warning in order to inform user that activation has occurred.
During the normal operation or the system installation the
Er36
error can be shown. The
main meaning of this error is that the radio link between the RSEC/R receiver and the
RSENS transmitter has been lost. In addition to the shown error, the RSEC/R receiver
will issue 6 beeps.
Summary of Contents for GAMMA VERSUS M20
Page 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door...
Page 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13...
Page 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13...
Page 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13...