GAMMA VERSUS MANUAL
13
COD. 1257066 Gamma VERSUS Manual v1.13
1 – ON
memorized a mechanical stop on closure and, therefore, will act
accordingly. In most cases, it will close until the mechanical stop is
found.
21
HALLB IN available
0 – OFF Enables the second Hall input (HALL_B).
1 – ON
22
Lock mode
0 – OFF Indicates the RSENS lock configuration, if it has been detected on
programming mode.
1 – ON
23
RBAND detected
0 – OFF Indicates the RBAND presence, if it has been detected on
programming mode.
1 – ON
24
Error info displayed
0 – OFF Enables the advanced level of errors/warnings displayed.
1 – ON
25
Pedestrian mode
0 – OFF Enables the pedestrian mode.
1 – ON
26
Motor outputs inverted
0 – OFF Enables the sense inversion of motor outputs.
1 – ON
27
Maximum speed close
0 – OFF Enables the closing action at maximum speed.
1 – ON
28
RBAND mode
0 – OFF Enables the RBAND mode.
1 – ON
29
RSENS mode
0 – OFF Enables the RSENS mode.
1 – ON
2A
RSENS detected
0 – OFF Indicates the RSENS presence, if it has been detected on
programming mode.
1 – ON
2B
Time/HALL autoconfig
0 – OFF Enables the automatic detection of time mode or Hall mode.
1 – ON
2C
Half Dead man mode
0 – OFF Enables the semi-deadman mode.
1 – ON
2E
Deadman if RSEC virgin
0 – OFF Enables dead man operating if a not programmed RSEC/R is
detected.
1 – ON
2F
Autodetect OptoEdge IN1 0 – OFF Indicates that the IN1 input is configured as optical edge input.
1 – ON
30
Autodetect OptoEdge IN2 0 – OFF Indicates that the IN2 input is configured as optical edge input.
1 – ON
31
Autodetect OptoEdge IN3 0 – OFF Indicates that the IN3 input is configured as optical edge input.
1 – ON
91
Pre-FLASH option
0 – OFF Enables the pre-flash function at the beginning of the manoeuvre.
1 – ON
92
RSENS Dynamic Radio
0 – OFF Enables the dynamic adjustment mode the radio power for the
RSENS.
1 – ON
B1
Block On/off by password
0 – OFF Enables the blockage of the control panel via password (default
value 0000).
1 – ON
B4
Current blockage status
0 – OFF Indicates if the control panel is blocked currently.
1 – ON
B6
Recharge maneuver
0 – OFF Enables the activation of the recharge maneuver during 3 seconds
each hour.
1 – ON
BD
Reverse strike at open
0 – OFF Enables the reverse strike at open
1 – ON
BE
Absolut encoder mode
0 – OFF Enables the operating by absolute encoder, that means that the
position control is done by the absolute encoder control
1 – ON
C1
Commercial mode
0 – OFF
1 - ON
Enable commercial mode, that means that the opening is done in
deadman or automatic mode and the closing always in deadman
mode.
C2
Programming forced
0 – OFF
1 - ON
Enable the programming sequence forced, that means that once the
control panel is power supplied, it enters automatically in
programming mode.
C3
Step by step sequence
0 – OFF
1 - ON
Enable step by step sequence operating through start button.
Summary of Contents for GAMMA VERSUS M20
Page 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door...
Page 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13...
Page 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13...
Page 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13...