GAMMA VERSUS MANUAL
16
COD. 1257066 Gamma VERSUS Manual v1.13
normally be the current limit that the panel will accept during operations at
slow speed.
45
Current margin
10
Level of sensitivity with which an obstacle due to overcurrent will be
detected during normal operations. In other words, the value that is added
to the memorised current curve and that stipulates the current limit
permitted at each movement point (motor power).
46
Norm/Low speed
factor
10
Ratio between the normal and slow speed of the door. The higher the
value, the lower speed.
47
Max.security
detections
10
Number of security trigger reversals permitted before auto-close is
inhibited. Where the door exceeds this maximum number of consecutive
closure reversals without being able to close completely, the auto-close
function will be disabled.
48
Max.autotests
before err.
10
Number of autotest repeats allowed before going out and showing error.
49
Time to close by
SEC.CL
1000
Waiting time before doing the closing movement by security contact.
4A
Electrolock time
10
Activation time of the electrolock.
4B
Courtesy light time 10
Activation time of the garage light.
4C
Flash frequency
10
Flash period time.
4D
Pre-flash time
10
Pre-flash time.
4E
Max.sequence
time
10
Maximum maneuver time.
4F
Press.time to
deadman
10
Needed pushing time of the Open or Close Pushbutton to enter to
deadman mode.
50
Panic signal period 10
Activation time of the panic signal.
51
Integrator value
TH1
1000
Integrator threshold 1 value (internal limit switch detection).
52
Integrator value
TH2
1000
Integrator threshold 2 value (internal limit switch detection).
53
RSENS
inhib.margin
10
Inhibition zone of the closing maneuver of RSENS.
93
Current margin in
PROG
10
Level of sensitivity with which an obstacle due to overcurrent will be
detected during programming.
94
AC Motor speed
regul.
10
AC motor power regulation value.
95
AC Motor LOW sp.
Regul.
10
AC motor power regulation value in slow speed.
B2
Password value
100(*)
Password's value for the blockage of the control panel.
B3
Inversion time by
SEC.CL
100
Inversion time after closing security detection.
B5
Traffic control
mode
10
Indicates the value of the traffic control mode.
C0
Maintenance
counter
100000000
Maintenance counter. It increases in each full maneuver (o
closing).
C7
Partial opening
time per inversion
on closing.
1000
Time of partial opening per inversion on closing.
Summary of Contents for GAMMA VERSUS M20
Page 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door...
Page 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13...
Page 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13...
Page 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13...