7.8 Deadman function
Model
All
Associated
parameters
ID
Description
Type
P07 Deadman
ON/OFF
P4F Press.time
to
deadman
NUMERIC
P5E...P77 IN
XX
INPUT
Description
The deadman function allows moving the door even securities are activated.
Configuration
To enable the deadman function it is needed to set to ON the
P07
configuration
parameter by means of a VERSUS-PROG programming tool. It is also possible to
enable or disable this function by setting the “Deadman ON/OFF” function to an option
switch.
The
P4F
configuration parameter allows modifying the button pressing time (button or
deadman transmitter) needed to enter to deadman mode if a security is active.
P5E
to
P77
parameters allow assigning an input value to every available control panel
input. “Open deadman” and “Close deadman” input values can be assigned to these
inputs. By using these inputs control panel enters directly to deadman mode.
Operating
There are four ways to enter to the deadman mode:
1 - Deadman mode enabled by
P07
configuration parameter. Every “open” and “close”
command (even by control panel button or deadman transmitter) will move the door in
deadman without taking into account the security inputs status.
2 - It is possible to enter to deadman mode, in programming state, by pressing the open
and close buttons in order to fix the door position before starting the programming
sequence.
3 – Control panel enters to deadman mode if there is any input configured as “Open
deadman” or “Close deadman” type and it is activated.
Summary of Contents for GAMMA VERSUS M20
Page 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door...
Page 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13...
Page 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13...
Page 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13...