8.4 Auto-Programming with internal limit switches detection
Follow the steps to perform the auto-programming with internal limit switches detection. It is necessary to
have the autoprogramming function activated
(P01 parameter)
and the internal limit switches detection
activated
(P1E parameter)
:
1. Door is in the totally closed position
2. Press PROG pushbutton to enter programming mode
3. The PROG Led will turn on
4. Press START pushbutton or a programmed transmitter to program the maneuver
5. The door opens two seconds and stops
6. The door closes automatically until the closed position
7. The door stops
8. The door opens automatically until a mechanical stop or a limit switch is reached
9. The door stops
10. The door closes automatically until a mechanical stop or a limit switch is reached
11. The door stops
12. The PROG Led turns off
13. The programming is finished
The control panel is programmed with the following fixed parameters: the pedestrian opening is 1/3 of the
total opening time and autoclosing time is 30 seconds (in total opening and in partial opening).