GAMMA VERSUS MANUAL
12
COD. 1257066 Gamma VERSUS Manual v1.13
1 – ON
12
Soft stop
0 – OFF Enables the soft stop function.
1 – ON
13
Radio CH1/2 config
0 – OFF
Configures the radio mode:
1- ON: channel 1 open, channel 2 close;
2 - OFF: channel 1 start, channel 2 pedestrian
1 – ON
14
Open slow start pt.
0 – OFF Enables slow starter before moving at normal speed at the start of
each maneuver of opening.
1 – ON
15
Close slow start pt.
0 – OFF Enables slow starter before moving at normal speed at the start of
each maneuver of closing.
1 – ON
16
Virtual ground ref.
0 – OFF
Enables the memorisation of the starting point of the programming
movement as the ground point. Most panels can only use this
parameter when operating by pulses. If this parameter is enabled,
the closure movement in programming will stop at this point. Where
it is disabled, the panel will not stop the closure movement until a
closure synchronism is received (end of run, mechanical stop, ALT,
etc.), going past this point if required. Likewise, if it is enabled,
movement operations by pulses will be counted on opening and if
disabled they will be counted on closure.
1 – ON
17
Reference Autosearch
0 – OFF
Enables the automatic reference search. Where enabled and
where, on connecting the panel, it has lost position with regards to
the reference/s, the panel will automatically search for the reference
without the need for any pulses or transmitters.
1 – ON
18
SEC.CL programmed
0 – OFF
Indicates if the closing security contact has been programmed
during the manoeuvre. The security contact inhibition during the
closing movement may not comply with regulations.
1 – ON
19
Substr. Bjump PROG
0 – OFF
This refers to the special function of subtracting the number of
pulses used in closure Back Jump from the total number of pulses of
the movement. In other words, if the closure Back Jump is enabled,
the panel will search for the closure reference during the door
programming process and will run the closure Back Jump. The point
where the door stops will be the virtual ground point. It will not
search for the ground reference again or run the closure Back Jump.
This only works with operations by pulses and where the closure
Back Jump is enabled. Once the panel has been programmed, the
closure Back Jump will be disabled. This must be taken into
account for later programming.
1 – ON
1A
Closing by CSEC
0 – OFF Enables the closure by security contact.
1 – ON
1B
HALL A type mode
0 – OFF Configures the HALL_A type (PNP/NPN) connected.
1- ON: PNP
0 - OFF: NPN
1 – ON
1C
HALL B type mode
0 – OFF Configures the HALL_B type (PNP/NPN) connected.
1- ON: PNP
0 - OFF: NPN
1 – ON
1D
Limit switch DC Mot
0 – OFF Enables the detection of mechanical stops by current (DC motors).
1 – ON
1E
Limit switch AC Mot
0 – OFF Enables the detection of mechanical stops by current (AC motors).
1 – ON
1F
Limit opening detected
0 – OFF
Indicates whether, during programming, the panel has found and
memorized a mechanical stop on opening and, therefore, will act
accordingly. In most cases, it will open until the mechanical stop is
found, adding pulses or time if required.
1 – ON
20
Limit closing detected
0 – OFF
Indicates whether, during programming, the panel has found and
Summary of Contents for GAMMA VERSUS M20
Page 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door...
Page 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13...
Page 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13...
Page 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13...