© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 2 3
Calibration and Testing
UBA™ Pro Series Universal Banknote Acceptor
Section 6
PB Motor Operation Test
To perform the PB Motor Operation Test, proceed as
follows:
1. Remove electrical power.
2. Set the DIP Switches as below (Figure 6-113).
3. Apply electrical power.
4. Confirm that the
Green
and
Red
Status LEDs are
lit.
5. Lift up on the Upper Guide Access Lever to open
the UBA Pro’s Cover
6. To start the Test, set the DIP Switch #8 to
OFF
7. The PB Guide will start moving when the PB
Motor functions properly.
8. Set the UBA Pro DIP Switch #8 to
ON
to end the
test.
Centering Motor Operation Test
To perform the Centering Motor Operation Test, pro-
ceed as follows:
1. Remove electrical power.
2. Set the DIP Switches as below (Figure 6-117).
3. Apply electrical power.
4. Confirm that the
Green
and
Red
Status LEDs are
lit.
5. Lift up on the Upper Guide Access Lever to open
the UBA Pro’s Cover
6. To start the Test, set the DIP Switch #8 to
OFF
(Figure 6-119).
7. The Centering Mechanism will start moving
when the Centering Motor functions properly.
8. Set the UBA Pro DIP Switch #8 to
ON
to end the
test.
Figure 6-113
PB Motor Operation 1
DIP Switches #5, #8 ON
ON
1
2
3
4
5
6
7
8
Figure 6-114
Figure 6-114
PB Motor Operation 2
Green Red
Figure 6-115
Figure 6-115
PB Motor Operation 3
DIP Switch #8 OFF
ON
1
2
3
4
5
6
7
8
Figure 6-116
PB Motor Operation 4
PB Guide
Figure 6-117
Centering Motor Operation 1
DIP Switches #1, #5, #8 ON
ON
1
2
3
4
5
6
7
8
Figure 6-118
Figure 6-118
Centering Motor Operation 2
Green Red
Figure 6-119
Figure 6-119
Centering Motor Operation 3
DIP Switch #8 OFF
ON
1
2
3
4
5
6
7
8
Figure 6-120
Figure 6-120
Centering Motor Operation 4
Centering Mechanism
Summary of Contents for UBA Pro Series