Calibration Error Codes; Position Sensor
Table A-9 lists the various Error Code causes and solutions for the Position Sensor.
UV (Transmissive)
Sensor
with Paper
05-00-00-00
Calibration Program process
failed.
•
Check that a correct Reference Paper is placed in
a proper direction. (Refer to “Placing Reference
•
Check that a Reference Paper is not damaged or
dirty. (Refer “Reference Paper Handling” on
•
Check that the relative part is properly
assembled and/or Harness are connected.
•
Clean the relative Sensor. (Refer to “Cleaning
Procedure” on page 2-17.)
•
UV Sensor
Validation Sensor
non-Paper
06-YYYY-YYYY-YYYY-YYYY
Calibration Program process
failed.
•
Check that a correct Reference Paper is placed in
a proper direction. (Refer to “Placing Reference
•
Check that a Reference Paper is not damaged or
dirty. (Refer “Reference Paper Handling” on
•
Check that the relative part is properly
assembled and/or Harness are connected.
•
Clean the relative Sensor. (Refer to “Cleaning
Procedure” on page 2-17.)
•
Line Sensor
UV (Transmissive)
Sensor
non-Paper
07-00-00-00
Calibration Program process
failed.
•
Check that a correct Reference Paper is placed in
a proper direction. (Refer to “Placing Reference
•
Check that a Reference Paper is not damaged or
dirty. (Refer “Reference Paper Handling” on
•
Check that the relative part is properly
assembled and/or Harness are connected.
•
Clean the relative Sensor. (Refer to “Cleaning
Procedure” on page 2-17.)
•
UV Sensor
Position Sensor
09-ZZ-ZZ-ZZ
Calibration Program process
failed.
•
Check that a correct Reference Paper is placed in
a proper direction. (Refer to “Placing Reference
•
Check that a Reference Paper is not damaged or
dirty. (Refer “Reference Paper Handling” on
•
Check that the relative part is properly
assembled and/or Harness are connected.
•
Clean the relative Sensor. (Refer to “Cleaning
Procedure” on page 2-17.)
•
Position Sensor
Table A-9
Position Sensor Calibration Error Codes
Sensor/Error
Error Code
Solutions
Relative
Parts/Sensors
Entrance Sensor
00-00-01
Calibration Program
process failed.
•
Check that a correct Reference Paper is placed in a
proper direction. (Refer to “Placing Reference Paper”
•
Check that a Reference Paper is not damaged or dirty.
(Refer “Reference Paper Handling” on page A-14.)
•
Check that the relative part is properly assembled and/
or Harness are connected.
•
Clean the relative Sensor. (Refer to “Cleaning
Procedure” on page 2-17.)
•
Entrance Sensor
Table A-8
Calibration Program Error Codes (Continued)
Calibration
Program
Error Code and
Causes
Solutions
Relative
Parts/Sensors